LCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.

High-Throughput Analysis of Epigenetic Targets with Agilent RapidFire/MS Systems: Sirtuin (SIRT) Enzymes

 

Podobná PDF

Toggle
Application Note Drug Discovery A study of SIRT1- and SIRT2‑Mediated Deacetylation Using the Agilent RapidFire high-throughput mass spectrometry system Authors Abstract Peter Rye, Lauren Frick, and William Lamarr Agilent Technologies, Inc. The Agilent RapidFire high-throughput mass spectrometry (MS) system is…
Klíčová slova
rapidfire, rapidfiresubstrate, substrateenzyme, enzymepeptide, peptidedeacetylation, deacetylationbluesky, blueskysirtuins, sirtuinsvelocities, velocitiesreactions, reactionslinear, linearcourse, courseutility, utilitybinding, bindingassays, assaysmodification
High-Throughput MS Detection of Histone H3 Demethylation by Lysine-Specific Demethylase 1 (LSD1) Application Note Author Introduction Peter Rye, Lauren Frick, and William LaMarr Agilent Technologies, Inc. Wakefield, MA USA The field of epigenetics focuses on the investigation of enzymes that…
Klíčová slova
rapidfire, rapidfireprotein, proteinconversion, conversionstudying, studyingepigenetic, epigeneticthroughput, throughputconcurrent, concurrentanalyze, analyzereaction, reactionwellsuited, wellsuitedlamarr, lamarrepigenetics, epigeneticsrelieves, relievesnative, nativeparticularly
Ultrafast Histone Deacetylase Selectivity Screening Using the Agilent RapidFire High-Throughput Mass Spectrometry System Application Note Authors Abstract Lauren E. Frick and William A. LaMarr Selectivity screening of a promising new compound requires testing against a Agilent Technologies, Inc. host of…
Klíčová slova
multiplex, multiplexunit, unitpos, posnormalized, normalizedsubstrate, substrateindividual, individualinhibition, inhibitionrapidfire, rapidfiremultiplexed, multiplexedtubacin, tubacinselectivity, selectivitybottleneck, bottleneckreactions, reactionsdeacetylase, deacetylasethroughput
High-Throughput Lead Discovery with Agilent RapidFire/MS Systems: Analysis of UDP-3-O-(R-3-hydroxymyristoyl)-NAcetylglucosamine Deacetylase (LpxC) Application Note Authors Introduction William Lamarr, Lauren Frick, and Peter Rye Agilent Technologies, Inc. Wakefield, MA USA The RapidFire High-throughput Mass Spectrometry System provides drug discovery researchers with…
Klíčová slova
lpxc, lpxcrapidfire, rapidfireinhibitors, inhibitorsenzyme, enzymesurrogate, surrogateimperfect, imperfectdiscovery, discoveryassay, assaythroughput, throughputhighthroughput, highthroughputantibacterial, antibacterialcumbersome, cumbersomesubstrates, substratessubstrate, substratetraditionally
Další projekty
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.