Spotting Fraction Impurities with More Confidence Using the Agilent 1290 Infinity II Preparative Open-Bed Sampler/Collector
Technické články | 2019 | Agilent TechnologiesInstrumentace
PrepLC
ZaměřeníVýrobceAgilent Technologies
Klíčová slovahomogenization, fraction, collector, reanalysis, fractions, bed, sampler, open, preparative, openlab, collected, chemstation, conveniently, cds, feature, mau, distributed, collection, after, obsoletes, spuling, overview, manual, irina, cycles, without, importance, mixing, runs, impurity, set, analytical, homogeneously, unintentionally, ambient, view, interaction, inhomogeneous, cornerstone, rieck, spotting, agilent, were, stretch, florian, impurities, demonstrates, increments, mode, operation
Podobná PDF
Reduce Your Purification Footprint: Scouting, Collection, and Reanalysis in Well Plates on a Single System
2020|Agilent Technologies|Technické články
Technical Overview Reduce Your Purification Footprint: Scouting, Collection, and Reanalysis in Well Plates on a Single System Author Florian Rieck Agilent Technologies, Inc. Abstract Typical purification workflows using high-performance liquid chromatography (HPLC) involve two systems: the analytical system is used…
Klíčová slova
preparative, preparativefractions, fractionspurification, purificationdilution, dilutionfraction, fractionsample, samplescouting, scoutingtarget, targetcollection, collectionmsd, msdanalytical, analyticalreinjection, reinjectionsoftware, softwaresamples, samplessandwich
Isolate and Reanalyze Pharma Impurities with the Agilent 1290 Infinity II Autoscale Preparative LC/MSD System
2020|Agilent Technologies|Aplikace
Application Note Pharmaceutical Small Molecules Isolate and Reanalyze Pharma Impurities with the Agilent 1290 Infinity II Autoscale Preparative LC/MSD System API Author Florian Rieck Agilent Technologies, Inc. Abstract Isolation of impurities for further characterization is a routine task in the…
Klíčová slova
preparative, preparativefraction, fractionmsd, msdreanalysis, reanalysisscale, scalefractions, fractionsreanalyzed, reanalyzedinjection, injectionmau, mauimpurities, impuritiesanalytical, analyticalopen, opensampler, samplerautoscale, autoscalecollector
Efficient Purification of Crude Samples in Early-Stage Drug Discovery Using the Agilent 1290 Infinity II Preparative LC/MSD System
2020|Agilent Technologies|Aplikace
Application Note Pharma & Biopharma Efficient Purification of Crude Samples in Early-Stage Drug Discovery Using the Agilent 1290 Infinity II Preparative LC/MSD System Authors Sonja Schipperges and Florian Rieck Agilent Technologies, Inc. Abstract In early-stage drug discovery, high-purity compounds are…
Klíčová slova
paracetamol, paracetamolpurification, purificationfraction, fractioncrude, crudescale, scalepreparative, preparativetarget, targetcompound, compoundimpurity, impuritypurity, puritycollector, collectormsd, msdpurified, purifiedrecovery, recoveryearly
Time-, Peak-, and Mass-Based Fraction Collection with the Agilent 1290 Infinity II Preparative Open-Bed Fraction Collector
2016|Agilent Technologies|Technické články
Time-, Peak-, and Mass-Based Fraction Collection with the Agilent 1290 Infinity II Preparative Open-Bed Fraction Collector Technical Overview Author Abstract Florian Rieck The Agilent 1290 Infinity II Preparative Open-Bed Fraction Collector sets new Agilent Technologies, Inc. benchmarks in efficient and…
Klíčová slova
collection, collectionfraction, fractionthreshold, thresholdcollector, collectorslice, sliceslope, slopebed, bedpreparative, preparativepeak, peaksignals, signalslogical, logicalmsd, msdupslope, upslopedownslope, downslopeopen