Peptide Quantification in Plasma Using the Agilent 6495 Triple Quadrupole LC/MS Coupled with the Agilent 1290 Infinity II LC System
Aplikace | 2020 | Agilent TechnologiesInstrumentace
LC/MS, LC/MS/MS, LC/QQQ
ZaměřeníProteomika
VýrobceAgilent Technologies
Klíčová slovasis, peptide, counts, peptides, acquisition, plasma, time, quantitative, sgipivtspyqihftk, min, mrm, quantification, lloq, human, aflltpr, sensitivity, agilent, apolipoprotein, amol, performance, targeted, response, analytical, excellent, standard, mixture, flow, jet, source, were, isotope, assessment, microflow, rrhd, stream, retention, transition, ajs, quadrupole, biomarker, from, zorbax, using, protein, blank, afamin, spiked, demonstrated, nine, outstanding
Podobná PDF
Comprehensive Protein Quantification in Plasma Using the Agilent 6495D Triple Quadrupole LC/MS System
2023|Agilent Technologies|Aplikace
Application Note Proteomics Comprehensive Protein Quantification in Plasma Using the Agilent 6495D Triple Quadrupole LC/MS System Author Linfeng Wu Agilent Technologies, Inc. Abstract This application note highlights the ultrahigh performance of the novel Agilent 6495D triple quadrupole liquid chromatography/mass spectrometry…
Klíčová slova
submillisecond, submillisecondpeptides, peptidessis, sisskyline, skylineresponse, responsetime, timeprotein, proteinatehlstlsek, atehlstlsekmrm, mrmacquisition, acquisitionpeptide, peptidedwell, dwellquantification, quantificationamol, amolplasma
Robust and Reproducible Protein Quantification in Plasma using the Evosep One and the Agilent 6495 Triple Quadrupole LC/MS
2020|Agilent Technologies|Aplikace
Application Note Proteomics Robust and Reproducible Protein Quantification in Plasma using the Evosep One and the Agilent 6495 Triple Quadrupole LC/MS Authors Linfeng Wu Agilent Technologies, Inc., Santa Clara, CA, USA Nicolai Bache and Dorte B. Bekker-Jensen Evosep Biosystems, Odense,…
Klíčová slova
robustness, robustnessevosep, evosepplasma, plasmapeptide, peptidesis, sisamol, amolhuman, humanmrm, mrmtest, testprotein, proteintargeted, targetedcolumn, columndigest, digestquantification, quantificationbefore
The Agilent 6495 Triple Quadrupole LC/MS: Peptide Quantitation Performance
2016|Agilent Technologies|Technické články
The Agilent 6495 Triple Quadrupole LC/MS: Peptide Quantitation Performance Technical Overview Introduction Sample complexity and the low concentration of certain biomarkers are the major challenges encountered when performing biomarker verification using multiple reaction monitoring (MRM)-based methods. For this reason, the…
Klíčová slova
contest, contestnanoflow, nanoflowpeptide, peptideflow, flowquantitation, quantitationplasma, plasmacounts, countsfmol, fmolquantitative, quantitativeperformance, performancestd, stdpeptides, peptidesstandard, standardamol, amolmrm
Agilent LC Triple Quadrupole Clinical Research Compendium
2021|Agilent Technologies|Příručky
Agilent LC Triple Quadrupole Clinical Research Compendium Application Compendium Table of contents Contents Introduction 4 Routine analysis 5 Hormones 5 Progesterone Metabolism in Serum 5 Analytical Determination of Testosterone in Human Serum Using an Agilent Ultivo Triple Quadrupole LC/MS 7…
Klíčová slova
atturos, atturoscounts, countsplasma, plasmaagilent, agilentstreamselect, streamselectserum, serummel, meltriple, triplecaptiva, captivaquadrupole, quadrupoleusing, usingthc, thctestosterone, testosteronemethod, methodacquisition