Determination of Nitrosamines in Active Pharmaceutical Ingredients
Aplikace | 2020 | Agilent TechnologiesInstrumentace
LC/MS, LC/MS/MS, LC/QQQ
ZaměřeníFarmaceutická analýza
VýrobceAgilent Technologies
Klíčová slovanitrosamine, accuracy, ndba, nitrosamines, nmor, nmea, ndpa, ndea, ultivo, ndma, npip, valsartan, pharmaceutical, gti, nitroso, dose, nitrosodimethylamine, prime, npyr, genotoxic, daily, impurities, solvent, intake, drug, rsd, dibutylamine, loq, nitrosomethylethylamine, nitrosomorpholine, agilent, api, nitrosodiethylamine, impurity, average, apis, propylamine, masshunter, flushing, describes, medicine, high, dna, duration, determination, excess, apci, ingredients, combination, agency
Podobná PDF
Improved LC/MS Performance to Determine Polar Nitrosamines Using the Agilent 1260 Infinity II Hybrid Multisampler
2024|Agilent Technologies|Aplikace
Application Note Biopharma/Pharma Improved LC/MS Performance to Determine Polar Nitrosamines Using the Agilent 1260 Infinity II Hybrid Multisampler Author Edgar Naegele Agilent Technologies, Inc. Abstract This application note demonstrates the use of the Agilent 1260 Infinity II Hybrid Multisampler for…
Klíčová slova
nitrosamines, nitrosaminesfeed, feedndma, ndmainjection, injectionnmor, nmornmea, nmeanpip, npipndpa, ndpandba, ndbandea, ndeanpyr, npyrflow, flownitrosodimethylamine, nitrosodimethylaminethrough, througheluting
Highly sensitive and robust LC-HRAM-MS method for simultaneous quantitation of sixteen nitrosamines in multiple drug products
2023|Thermo Fisher Scientific|Aplikace
Application note | 001657 Pharma Highly sensitive and robust LC-HRAM-MS method for simultaneous quantitation of sixteen nitrosamines in multiple drug products Goal Authors Krishna Mane , Venkatesh Chanukuppa , The aim of this study was to evaluate and report on…
Klíčová slova
prm, prmnipma, nipmannea, nneanitroso, nitrosonda, ndandpha, ndphanitrosamine, nitrosaminenmpa, nmpanmor, nmormetformin, metforminnmba, nmbanmea, nmeanpyr, npyrnpip, npipneipa
Determination of Nitrosamine Impurities Using the Agilent 6475 Triple Quadrupole LC/MS System
2023|Agilent Technologies|Aplikace
Application Note Pharma/Biopharma Determination of Nitrosamine Impurities Using the Agilent 6475 Triple Quadrupole LC/MS System Authors Linfeng Wu and Lee Bertram Agilent Technologies, Inc. Santa Clara, CA, U.S. Shan-An Chan Agilent Technologies, Inc. Taiwan Abstract Nitrosamine impurities are by-products that…
Klíčová slova
nitrosamine, nitrosaminenmor, nmorresponses, responsesndma, ndmanmea, nmeanpyr, npyrnpip, npipndpa, ndpandba, ndbandea, ndeacounts, countsconcentration, concentrationlosartan, losartanblocker, blockerdrug
Determination of Nitrosamine Impurities Using the Agilent 6495D Triple Quadrupole LC/MS System
2023|Agilent Technologies|Aplikace
Application Note Determination of Nitrosamine Impurities Using the Agilent 6495D Triple Quadrupole LC/MS System Authors Abstract Lee Bertram and Linfeng Wu Agilent Technologies, Inc. Nitrosamine impurities are byproducts produced in trace amounts during the manufacture of pharmaceutical drugs. These impurities…
Klíčová slova
fragile, fragilenitrosamine, nitrosaminenpyr, npyrnmor, nmorresponses, responsesndma, ndmanmea, nmeanpip, npipndpa, ndpandba, ndbandea, ndealosartan, losartandrug, drugacquisition, acquisitionmin