Multi-Attribute Analysis of Monoclonal Antibodies Using the Agilent InfinityLab 2D-LC Solution and Q-TOF MS
Aplikace | 2020 | Agilent TechnologiesInstrumentace
LC/TOF, LC/HRMS, LC/MS, LC/MS/MS, 2D-LC
ZaměřeníFarmaceutická analýza
VýrobceAgilent Technologies
Klíčová slovamab, clone, protein, sec, heart, cutting, mau, tocilizumab, actemra, counts, originator, supernatants, dimension, variants, main, cho, titer, min, column, clones, lmw, mol, valve, deconvoluted, from, mobile, cell, therapeutic, rplc, multiple, attribute, chromatography, amu, glycosylation, pump, phase, loop, affinity, producing, area, mass, culture, size, gradient, detection, antibodies, timetable, monoclonal, desalted, monolith
Podobná PDF
Determination of Multiple Attributes of Monoclonal Antibodies
2021|Agilent Technologies|Aplikace
Application Note Biopharma/Pharma Determination of Multiple Attributes of Monoclonal Antibodies Simultaneous and parallel multi-attribute analysis using 3D-LC/MS with 2D multimethod option mAb SEC Size variants Protein A CEX LC/MS mAb Titer Charge variants Mol wt (MW) AA sequence PTM Cell…
Klíčová slova
trastuzumab, trastuzumaboriginator, originatorcex, cexmau, mauhic, hichmw, hmwcho, choprotein, proteinvariants, variantscounts, countsdeconvoluted, deconvolutedclone, cloneclones, clonesmin, minvalve
Agilent AdvanceBio Desalting-RP Cartridges for Online Desalting in 2D‑LC/MS mAb Analysis
2016|Agilent Technologies|Aplikace
Agilent AdvanceBio Desalting-RP Cartridges for Online Desalting in 2D‑LC/MS mAb Analysis Application Note Biotherapeutics and Biologics Authors Abstract Suresh Babu C.V. and Ravindra Gudihal This Application Note describes the use of a desalting cartridge in the second Agilent Technologies, Inc.…
Klíčová slova
desalting, desaltingadvancebio, advancebiodimension, dimensionmab, mabsecond, seconddeconvoluted, deconvolutedagilent, agilentinnovator, innovatorbiosimilar, biosimilarheart, heartprotein, proteincutting, cuttingmau, maucartridges, cartridgesvariants
Clone Selection Using the Agilent 1290 Infinity Online 2D-LC/MS Solution
2016|Agilent Technologies|Aplikace
Clone Selection Using the Agilent 1290 Infinity Online 2D-LC/MS Solution Application Note Biopharmaceuticals Authors Abstract Ravindra Gudihal and This Application Note describes the Agilent 1290 Infinity online 2D-LC/MS Syed Salman Lateef solution and proof of principle for clone selection and…
Klíčová slova
counts, countsbiosimilar, biosimilarclone, clonedeconvoluted, deconvolutedamu, amumass, massinnovator, innovatoragilent, agilentcharge, chargepurification, purificationdesalting, desaltingrituximab, rituximabmin, minprotein, proteinmab
2D-LC/MS Characterization of Charge Variants Using Ion Exchange and Reversed-Phase Chromatography
2020|Agilent Technologies|Aplikace
2D-LC/MS Characterization of Charge Variants Using Ion Exchange and Reversed-Phase Chromatography Multiple Heart-Cutting 2D-LC Analysis of Innovator versus Biosimilar Monoclonal Antibodies Application Note Biotherapeutics and Biologics Author Abstract Sonja Schneider The determination of charge variants is one of the most…
Klíčová slova
dimension, dimensionbiosimilar, biosimilarsalt, saltinnovator, innovatorvariants, variantscharge, chargerituximab, rituximabfirst, firstsecond, secondmain, mainwaste, wastebuffer, bufferphosphate, phosphatevariant, variantdeconvoluted