Deep Characterization of Aspartic Acid Isomerism Using High-Resolution Cyclic™ Ion Mobility and Electron-Capture Dissociation

Aplikace | 2026 | WatersInstrumentace
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS, Iontová mobilita
Zaměření
Farmaceutická analýza
Výrobce
Waters
PDF verze ke stažení a čtení
 

Podobná PDF

Toggle
In-Depth Versatile Characterization of Aspartic Acid Isomers via a Cyclic Ion Mobility Mass Spectrometry (cIMS)
In-Depth Versatile Characterization of Aspartic Acid Isomers via a Cyclic Ion Mobility Mass Spectrometry (cIMS) Samantha Ippoliti1; Brad J. Williams1, Dale Cooper-Shepherd2, Ying Qing Yu1, Weibin Chen1, Barbara Sullivan1, James I. Langridge2 1Waters Corporation, Milford, MA, USA; 2Waters Corporation, Wilmslow,…
Klíčová slova
asp, aspcims, cimsisoasp, isoaspmobility, mobilitytmab, tmabims, imscyclic, cyclicspecies, speciesvia, viahdms, hdmspeptides, peptidesaspartic, asparticion, ionbiotherapeutic, biotherapeutictryptic
Electron Capture Dissociation in Combination With High Performance Cyclic Ion Mobility Separation for Detailed Protein Studies
Application Note Electron Capture Dissociation in Combination With High Performance Cyclic Ion Mobility Separation for Detailed Protein Studies Dale Cooper-Shepherd Waters Corporation This is an Application Brief and does not contain a detailed Experimental section. Abstract Electron capture dissociation (ECD)…
Klíčová slova
mobility, mobilitycyclic, cyclicdissociation, dissociationcapture, captureprotein, proteinelectron, electronstudies, studiesdetailed, detailedcombination, combinationseparation, separationecd, ecdion, ionions, ionsperformance, performancehigh
Identification of Amino Acid Isomers Using Electron Capture Dissociation in the Agilent 6545XT AdvanceBio LC/Q-TOF System
Application Note Biopharma Identification of Amino Acid Isomers Using Electron Capture Dissociation in the Agilent 6545XT AdvanceBio LC/Q-TOF System Authors Rachel Franklin and Joseph Meeuwsen Agilent Technologies, Inc. Abstract Accurately determining the amino acid sequence is crucial for understanding a…
Klíčová slova
fragmentation, fragmentationexd, exdisoasp, isoaspleu, leuecd, ecdile, ileelectron, electronisobaric, isobaricexdviewer, exdvieweramino, aminoside, sidecell, cellchain, chainreallyisodelightflk, reallyisodelightflkpeptide
Structural Characterization of Multiple GLP-1 Receptor Agonists using Electron Capture Dissociation
Poster Reprint ASMS 2025 Poster number WP 603 Structural Characterization of Multiple GLP-1 Receptor Agonists using Electron Capture Dissociation Rachel Franklin1; Julie Horner-Buxton2; Joseph C. Meeuwsen1; Thomas E. Walker3; Mike Hare1 1Agilent Technologies, Inc., Corvallis, OR; 2Agilent Technologies, Santa Clara,…
Klíčová slova
exdviewer, exdviewerfragmentation, fragmentationamino, aminoisoaspartate, isoaspartateecd, ecdmodification, modificationsequence, sequenceacids, acidsevidence, evidencevisualizing, visualizingdeconvolution, deconvolutionfragment, fragmentisomeric, isomericionscore, ionscoredissociation