Two-In-One Bioprocess Analytics - Combining mAb titer determination and spent media analysis by internal valve switching using the Agilent 1260 Infinity II Bio-Inert LC and InfinityLab LC/MSD iQ
Aplikace | 2020 | Agilent TechnologiesInstrumentace
HPLC, LC/MS, LC/SQ
ZaměřeníFarmaceutická analýza
VýrobceAgilent Technologies
Klíčová slovacultivation, glutamine, alanyl, msd, mab, acid, process, lactic, spent, cultivations, glucose, infinitylab, cell, media, titer, cho, threonine, isoleucine, glutamic, serine, were, alanine, phenylalanine, tyrosine, glycine, methionine, leucine, lysine, affinity, culture, bioprocess, growth, aspartate, supernatants, valve, protein, product, area, nutrients, upstream, agilent, ich, analysis, parameters, lglutamine, subsequential, formate, coupled, daily, fragmentor
Podobná PDF
High-Performance Biopharma Analysis - Application compendium
2021|Agilent Technologies|Příručky
Agilent InfinityLab Bio LC Solutions High-Performance Biopharma Analysis Application compendium 2 Overcome Analytical Challenges in Biopharma The growing complexity of biopharma analysis calls for innovation that delivers excellence across the biopharmaceutical workflow. The Agilent InfinityLab Bio LC Solutions comprise a…
Klíčová slova
retention, retentionbio, biomin, mingradient, gradienttime, timenistmab, nistmabresponse, responsemau, maupeptide, peptidemapping, mappingagilent, agilentcharge, chargersd, rsdmab, mabantibody
Analysis of Underivatized Amino Acids and Metabolites in Cell Culture Media by HILIC-LC/MS
2018|Agilent Technologies|Postery
Poster Reprint ASMS 2018 MP-566 Analysis of Underivatized Amino Acids and Metabolites in Cell Culture Media by HILIC-LC/MS Anne E. Blackwell1, Richard Hurteau1, Jordy J. Hsiao2, Te-Wei Chu2, Suma Ramagiri1 Agilent Technologies, Inc., Wilmington, DE USA 1 2 Agilent USA…
Klíčová slova
media, mediaculture, culturebioreactor, bioreactorglutamine, glutaminespent, spentamino, aminomobile, mobileglucose, glucosehollow, hollowmab, mabmonolith, monolithtiter, titerisoleucine, isoleucinebluensidine, bluensidinevitamins
Investigation of Human Embryo Culture Media Using a Quadrupole Time-of-Flight (Q-TOF) Mass Spectrometer
2019|Shimadzu|Postery
MP 313 Investigation of Human Embryo Culture Media Using a Quadrupole Time-of-Flight (Q-TOF) Mass Spectrometer Helen Hao1,2, Evelyn Wang1, Jennifer Davis1, Jerry Byrne II1, Katie Pryor1, and Christopher Gilles1 Scientific Instruments, Inc. Columbia, MD, USA; 2 Shimadzu (China) Co., LTD.…
Klíčová slova
embryo, embryoalanyl, alanylacid, acidsodium, sodiumglutamine, glutamineglucose, glucosepyruvic, pyruvicimprobable, improbablethreonine, threoninehistidine, histidineproline, prolinevaline, valineisoleucine, isoleucinecitrate, citrateaspartic
Analysis of Underivatized Amino Acids by LC/MS for Bioreactor Cell Culture Monitoring
2018|Agilent Technologies|Aplikace
Application Note Analysis of Underivatized Amino Acids by LC/MS for Bioreactor Cell Culture Monitoring Authors Abstract Jordy Hsiao, Te-Wei Chu, Andrew Kennedy, Adam Bivens, and Anne Blackwell This Application Note presents a solution for LC/MS analysis of amino acids in…
Klíčová slova
counts, countsacquisition, acquisitionmin, minbioreactor, bioreactortime, timeeic, eicesi, esiglucose, glucosehydrochloride, hydrochloridethreonine, threoninevaline, valineisoleucine, isoleucineglutamine, glutamineserine, serinearginine