Chromatography in the Express Lane High Resolution, Fast LC
Prezentace | 2016 | Agilent TechnologiesInstrumentace
HPLC
ZaměřeníVýrobceAgilent Technologies
Klíčová slovaconfidential, agilent, volume, resolution, increase, gradient, mau, time, column, run, decrease, plates, min, flow, extra, what, rate, increased, naphthalene, length, minimize, isocratic, vinj, dwell, theoretical, uhplc, number, system, separations, loss, needs, reduce, size, injection, instrument, reduced, particle, height, pressure, bar, hplc, shorter, design, equilibration, higher, current, your, acetonitrile, delay, width
Podobná PDF
Updating Old Methods:Is the Gain Worth the Pain? - Becoming a Better Chromatographer HPLC educational webinar
2019|Agilent Technologies|Prezentace
Updating Old Methods: Is the Gain Worth the Pain? Becoming a Better Chromatographer HPLC educational webinar Mark Powell Applications Engineer Columns and Supplies Technical Support Why Would You Consider Updating? What Is the Goal? • Do I need to update?…
Klíčová slova
mau, mauchiral, chiralinfinitylab, infinitylabmin, minporoshell, poroshellparticle, particlecolumn, columnagilent, agilentdeemter, deemterdiffusion, diffusionallowed, allowedvan, vanchanges, changesphase, phasemobile
High Resolution Fast LC - Easier Than You Think
2013|Agilent Technologies|Prezentace
High Resolution Fast LC Easier Than You Think Rita Steed LC Columns Application Engineer May 9, 2013 What is High Resolution Fast LC? • Maintain Resolution with Faster Run Time • Increased Resolution with Faster Run Time • Increasing Speed…
Klíčová slova
res, resrestricted, restrictedfast, fastagilent, agilentvolume, volumehigh, highcolumn, columngradient, gradientmau, maumin, mintime, timelength, lengthdelay, delayextra, extrahplc
There’s a lot to Learn: Tips for Avoiding Pitfalls
2015|Agilent Technologies|Prezentace
There’s a lot to Learn: Tips for Avoiding Pitfalls Mark Powell LC Columns Application Engineer January 19, 2015 Overview Instrument • Connections • Performance Column • Characteristics • Lifetime Method • Mobile phase • Temperature Sample • Cleanup • Injection…
Klíčová slova
beginner, beginnerpitfalls, pitfallsavoiding, avoidingrestricted, restrictedagilent, agilentconfidentiality, confidentialitymobile, mobilecolumn, columnlabel, labelphase, phasemin, minfittings, fittingspitfall, pitfallfitting, fittingmau
LC Column Troubleshooting - Isolating the Source of the Problem
2013|Agilent Technologies|Prezentace
LC Column Troubleshooting Isolating the Source of the Problem Rita Steed December 12, 2013 Page 1 What Do We Troubleshoot The typical LC troubleshooting approach asks the questions: – What’s wrong with the column? – What’s wrong with the instrument?…
Klíčová slova
column, columntailing, tailingmin, minmau, mauvolume, volumemobile, mobilefittings, fittingspeak, peakphase, phaseplugged, pluggedpeaks, peakstime, timefrit, fritred, redextra