New innovations implemented on the Q Exactive HF mass spectrometer
Postery | 2017 | Thermo Fisher ScientificInstrumentace
LC/HRMS, LC/MS, LC/MS/MS, LC/Orbitrap
ZaměřeníVýrobceThermo Fisher Scientific
Klíčová slovaexactive, qehf, electrodynamic, hctt, funnel, protein, peptides, groups, calmix, ion, average, mass, aabg, overhead, improvements, unique, intact, flux, scan, trastuzumab, capacity, advanced, negetive, abundance, tube, beam, time, scheffler, monoclonal, antibody, frequency, differentiator, relative, orbitrap, transfer, molecule, hyperquad, dependent, new, guide, aqt, aiming, electrometer, kai, analysis, high, paroxetine, active, kindly, slides
Podobná PDF
Thermo Scientific Q Exactive HF-X Hybrid Quadrupole-Orbitrap MS System - PRODUCT SPECIFICATIONS
2017|Thermo Fisher Scientific|Brožury a specifikace
PRODUCT SPECIFICATIONS Thermo Scientific Q Exactive HF-X Hybrid Quadrupole-Orbitrap MS System • Scan speed up to 40 Hz with ultra-high-field Thermo Scientific™ Orbitrap™ mass analyzer technology • Resolution of up to 240,000 (FWHM) at m/z 200 • High Capacity Transfer…
Klíčová slova
ion, ionexactive, exactivemass, massorbitrap, orbitrapthermo, thermohctt, hcttflow, flowdata, datascan, scanelectrodynamic, electrodynamicahcd, ahcdscientific, scientificvacuum, vacuumacquisition, acquisitionhigh
Relative quantification using TMT11plex on a modified Q Exactive HF mass spectrometer
2017|Thermo Fisher Scientific|Postery
Relative quantification using TMT11plex on a modified Q Exactive HF mass spectrometer Tabiwang N. Arrey,1 Rosa Viner,2 Ryan D. Bomgarden,3 Eugen Damoc,1 Markus Kellmann,1 Thomas Moehring,1 and Alexander Harder1. 1Thermo Fisher Scientific (Bremen) GmbH, Hanna-Kunath-Str. 11, 28199 Bremen, 2Thermo Fisher…
Klíčová slova
exactive, exactivequantified, quantifiedidentified, identifiedavergae, avergaepeptides, peptidesgroups, groupsprotein, proteinisolation, isolationaverage, averagewidth, widthproteins, proteinsconsenseus, consenseusisobaric, isobaricconc, concworkflow
Performance Evaluation of a Modified Quadrupole Orbitrap Mass Spectrometer
2019|Thermo Fisher Scientific|Postery
Performance Evaluation of a Modified Quadrupole Orbitrap Mass Spectrometer Tabiwang N. Arrey1, Rosa Jersie-Christensen Rakownikow1, Julia Kraegenbring1, Kerstin Strupat1, Markus Kellmann1, Catharina Crone1, Thomas Moehring1, Alexander Harder1 1Thermo Fisher Scientific, Bremen, Bremen, Germany Results: The novel Orbitrap Exploris 480 mass…
Klíčová slova
protein, proteinpeptides, peptidesgroups, groupsyeast, yeastcompensention, compensentionnofiams, nofiamsunique, uniquenofaims, nofaimsmpi, mpimin, minnew, newaabg, aabgrouting, routingfaims, faimsorbitrap
Improving high-throughput Top-Down proteomics using a modified hybrid quadrupole-ultra-high-field-Orbitrap mass spectrometer
2017|Thermo Fisher Scientific|Postery
Improving high-throughput Top-Down proteomics using a modified hybrid quadrupole-ultra-high-field-Orbitrap mass spectrometer Eugen Damoc1, Kyle L. Fort2, Michiel van de Waterbeemd2, Sem Tamara2, Christian Thoeing1, Erik Cousijn1, Tabiwang Arrey1, Alexander Harder1, Albert J. R. Heck2 and Alexander Makarov1 Fisher Scientific (Bremen)…
Klíčová slova
ftms, ftmsabundance, abundancedda, ddatop, topdown, downrelative, relativesliding, slidingdeconvolution, deconvolutionhigh, highmasses, massesesi, esifull, fullwindow, windowxtract, xtractproteins