LCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.

Agilent RapidFire 400 high-throughput mass spectrometry system

 

Podobná PDF

Toggle
RapidFire for Automated High-Throughput LC/MS
RapidFire for Automated High-Throughput LC/MS
2023|Agilent Technologies|Příručky
RapidFire for Automated High-Throughput LC/MS Proven. Rapid. Complete. Application Compendium Table of Contents Introduction3 Application Notes Method Development High-Throughput (Sub-2.5 Second) Direct Injection Analysis by  Mass Spectrometry 4 Automated Method Development Using the Agilent RapidFire  High-Throughput Mass Spectrometry…
Klíčová slova
rapidfire, rapidfirecounts, countsthroughput, throughputsip, sipwere, wereoligo, oligomass, masstof, tofagilent, agilentcartridge, cartridgehigh, highmethod, methoddata, dataoligos, oligosfrom
Ultrafast Analysis of Metabolic Stability Assays using an Agilent Ultivo Triple Quadrupole LC/MS
Application Note Drug Discovery Ultrafast Analysis of Metabolic Stability Assays using an Agilent Ultivo Triple Quadrupole LC/MS Author Kevin McCann Agilent Technologies, Inc. Abstract A previous Application Note1 highlighted the advantages of using the Agilent RapidFire 365 high-throughput MS to…
Klíčová slova
rapidfire, rapidfireultivo, ultivopropafenone, propafenonenicardipine, nicardipineticlopidine, ticlopidinethioridazine, thioridazinemetabolic, metabolicremaining, remainingfluconazole, fluconazolehaloperidol, haloperidolpromethazine, promethazineclearance, clearancebuffer, bufferamitriptyline, amitriptylineagilent
Ultrafast Plasma Protein Binding Analysis
Ultrafast Plasma Protein Binding Analysis
2022|Agilent Technologies|Aplikace
Application Note Ultrafast Plasma Protein Binding Analysis Using the Agilent RapidFire high-throughput mass spectrometry system and accurate mass Q-TOF Authors Abstract Kari E. Schlicht and Vaughn P. Miller Agilent Technologies, Inc. There has been increased demand for higher throughput in…
Klíčová slova
bound, boundrapidfire, rapidfiretof, tofspe, spedialysis, dialysisvoltage, voltagesheath, sheathwere, wereequilibrium, equilibriumthroughput, throughputgas, gasmethod, methoddrying, dryingplasma, plasmarate
Only Agilent Covers All Your Mass Spec Needs
Only Agilent Covers All Your Mass Spec Needs
2016|Agilent Technologies|Brožury a specifikace
Only Agilent Covers All Your Mass Spec Needs ANY ANALYTE, ANY METHOD, ONE PARTNER WHERE SOLUTIONS COME TOGETHER The best solutions don’t come together by accident. Decades of experience designing mass spec systems gives us a clear advantage, but we…
Klíčová slova
agilent, agilentsystems, systemsour, ouryou, youicp, icpyour, yourattogram, attograminert, inertself, selfdeliver, delivercleaning, cleaninghelp, helpultra, ultramasshunter, masshunterpath
Další projekty
GCMS
ICPMS
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.