LCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.
Pořadatel
Bruker
Bruker
Bruker nabízí nejkomplexnější škálu vědeckých přístrojů na světě, které jsou k dispozici pod jednou značkou - značka je synonymem excelence, inovace a kvality.
Tagy
LC/MS
LC/MS/MS
LC/IT
LinkedIn Logo

Moving Away From Immunoassays: Adapting LC-MS for Routine Urine Toxicology Screens

ZÁZNAM | Proběhlo St, 16.12.2020
Tento webinář se zaměří na LC-MSn metodu Toxtyper Drugs of Abuse (DOA) a její srovnání s aktuálně používanými imunotesty (CEDIA, EMIT a DRI) pro rutinní toxikologické monitorování moči.
Přejít na webinář
Bruker Daltonics: Moving Away From Immunoassays: Adapting LC-MS for Routine Urine Toxicology Screens
Bruker Daltonics: Moving Away From Immunoassays: Adapting LC-MS for Routine Urine Toxicology Screens

Immunoassays dominate the drug screen assay market as the most widely used method for routine urine toxicology screens. However, this method of analysis lacks specificity and suffers from cross-reactivity with irrelevant, similarly structured compounds. Furthermore, not all immunoassays are sensitive to drug metabolites, leading to false negatives. These limitations lead to the need for confirmation testing by LC-MS/MS, which has longer turnaround times. The Toxtyper is an automated LC-MSn coupled with a method-specific library search engine and compound identification algorithm. Its push-button interface is designed for implementation in the lab without the need for toxicology trained staff.

This webinar will be focused on the Toxtyper drugs-of-abuse (DOA) LC-MSn method and how it compares with the currently used immunoassays (CEDIA, EMIT and DRI) for urine toxicology routine panels in terms of sensitivity, number of compounds identified, speed, and sample preparation. The comparative study conducted by Dr. Adina Badea, PhD, DABCC, demonstrated that the Toxtyper provides consistent results with commonly used immunoassay screens, within a competitive timeframe. Furthermore, the added information and specificity provided by the LC-MSn system can have a significant impact in optimization of patient care.

Key Learning Objectives:

  • Comparison between the Toxtyper LC-MS and conventional immunoassays
  • Avantages of using the Toxtyper system to optimize patient care
  • Using the Toxtyper to elucidate unusual exposures in the emergency medicine setting

Who Should Attend:

  • Toxicologists
  • Medical Examiners
  • Toxicology Lab Supervisors

For Research Use Only. Not for use in clinical diagnostic procedures.

Presenter: Adina Badea (Director of Toxicology at Lifespan / Rhode Island Hospital)

Dr. Adina Badea, PhD, DABCC, received her clinical chemistry and toxicology training from UCSF, where she worked under the supervision of Dr. Alan Wu and Dr. Kara Lynch on developing methods and finding new solutions to current challenges in clinical toxicology testing. Currently she is Director of Toxicology at Rhode Island Hospital and Assistant Professor of Pathology and Laboratory Medicine at The Warren Alpert Medical School of Brown University, where she focuses on expanding the capabilities of the clinical toxicology lab using high resolution mass spectrometry and investigating emerging matrices.

Bruker
LinkedIn Logo
 

Mohlo by Vás zajímat

Benefits of Agilent Altura Ultra Inert HPLC Column Hardware

Aplikace
| 2026 | Agilent Technologies
Instrumentace
Spotřební materiál, LC kolony
Výrobce
Agilent Technologies
Zaměření
Životní prostředí

Vinylene carbonate water determination via coulometric Karl Fischer titration

Aplikace
| 2026 | Metrohm
Instrumentace
Titrace Karl Fischer, Voltametrie/Coulometrie
Výrobce
Metrohm
Zaměření
Polovodiče

An Isocratic Separation of B Vitamins Using Waters XBridge Biphenyl RP Column with MaxPeak Premier Technology

Aplikace
| 2026 | Waters
Instrumentace
Spotřební materiál, LC kolony
Výrobce
Waters
Zaměření
Farmaceutická analýza

Impurity Monitoring of GLP-1 Therapeutic Peptide RetatrutideUsing a 2D-LC/TOF System

Postery
| 2026 | Agilent Technologies (ASMS)
Instrumentace
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS, 2D-LC
Výrobce
Agilent Technologies
Zaměření
Farmaceutická analýza

Increased sensitivity for low-input label-free proteomics using the Orbitrap Astral MS and μPAC Neo Plus Columns

Aplikace
| 2026 | Thermo Fisher Scientific
Instrumentace
LC/HRMS, LC/Orbitrap, LC/MS, LC/MS/MS
Výrobce
Thermo Fisher Scientific
Zaměření
Proteomika
Další projekty
GCMS
ICPMS
Sledujte nás
FacebookX (Twitter)LinkedInYouTube
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.