LCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.
Pořadatel
C&EN
C&EN
Chemical & Engineering News (C&EN) je vlajkovým časopisem American Chemical Society, organizace s více než 157 000 členy ve více než 100 zemích. "Like" C&EN, pokud jste profesionál, který hledá novinky z chemie, nebo jste prostě fanouškem chemie.
Tagy
LC/MS
LC/MS/MS
Příprava vzorků
SPE
LinkedIn Logo

Eliminating Matrix Effects in Lipid-rich, Full-Fish Homogenates

ZÁZNAM | Proběhlo Út, 25.2.2025
V tomto webináři se dozvíte, jaká jsou omezení metody pH podle EPA 1633 při analýze homogenátů z ryb bohatých na lipidy.
Přejít na webinář
Phenomenex: Eliminating Matrix Effects in Lipid-rich, Full-Fish Homogenates
Phenomenex: Eliminating Matrix Effects in Lipid-rich, Full-Fish Homogenates

Extracting PFAS from dirty matrices is a challenging task. With the finalization of the EPA Method 1633 (Analysis of Per- and Polyfluoroalkyl Substances in Aqueous, Solid, Biosolids, and Tissue Samples by LC-MS/MS), the scientific community is closer to reaching that goal. However, the basic pH method in EPA 1633 is not suitable for some of the most complicated matrices, including lipid-rich, full-fish homogenates. Basic methods are lipid-limited and there is an increased likelihood of incomplete separation of PFAS due to significant matrix interferences. This poses a challenge for analyzing PFAS in whole fish (as opposed to fillets or organs) which can provide valuable information about both human and animal exposure through consumption.

In addition, many methods focus on the analysis of PFAS in fish fillets with the primary purpose of informing human consumption advisories. However, this is likely not representative of the PFAS burden consumed by aquatic predators, who generally eat most of the fish, if not all. Some internal organs, such as the liver, have higher concentrations of PFAS than the fillet. Analyzing the homogenate of a whole fish provides a holistic view of animal exposure through consumption, as well as exposure for the fish itself.

We developed an extraction method that can be used to analyze linear perfluorocarboxylic & perfluorosulfonic acids in lipid-rich, full-fish homogenates. Recoveries of PFCAs & PFSAs were between 73 and 104%, which is comparable, if not improved from, the acceptable range in EPA 1633. This method allowed us to analyze homogenized Pacific Herring and Chinook salmon samples. EPA Method 1633 was tested on these samples, but there was no recovery of target analytes. Using the method in this presentation, linear PFCAs were detected 54% of the time with an average concentration and SEM of 5.2±1.9 ng/g ww. Linear PFSAs were detected in 73% of samples with an average concentration of 1.6±0.2 ng/g ww. As with most other biological samples, the profile of linear PFSAs was predominantly PFOS, which had a detection frequency of 73% and an average concentration of 1.4±0.2 ng/g ww..

While this method does have trade-offs with EPA Method 1633, including a smaller amenable suite of analytes, it can be used to determine trophic magnification of PFAS more accurately. Additionally, this method can be used on banked fish samples that have been homogenized before storage, providing an opportunity for historical sample analysis.

Key Objectives:

  • Understand the limitations of the basic pH method in EPA 1633 when analyzing lipid-rich, full-fish homogenates.
  • Explore a new extraction method that can be used to analyze linear perfluorocarboxylic and perfluorosulfonic acids for a more efficient and accurate analysis.

Presenter: Richard Jack, Ph.D., (Global Market Development Manager, Phenomenex)

Presenter: Sydney Brady (Ph.D. Candidate, Indiana University O´Neill School of Public and Environmental Affairs, Bloomington, IN)

C&EN
LinkedIn Logo
 

Mohlo by Vás zajímat

Overcoming Strong Solvent Effects in the Analysis of Vepdegestrant

Aplikace
| 2026 | Agilent Technologies
Instrumentace
HPLC
Výrobce
Agilent Technologies
Zaměření
Farmaceutická analýza

Identification of Double Bond Positions and Relative Acyl Chain Positions in Egg Yolk Phosphatidylcholines Using OAD-TOF System

Aplikace
| 2026 | Shimadzu
Instrumentace
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS
Výrobce
Shimadzu
Zaměření
Potraviny a zemědělství

High Molecular-Weight Polysaccharide Characterization by SEC-MALS Using GTxResolve™ 1000 and 2000 Å SEC Columns

Aplikace
| 2026 | Waters
Instrumentace
GPC/SEC, Spotřební materiál, LC kolony
Výrobce
Waters
Zaměření
Farmaceutická analýza, Potraviny a zemědělství

Development and Optimization for a Comprehensive LC/MS/MS Method for the Detection of 74 PFAS Compounds

Aplikace
| 2026 | Agilent Technologies
Instrumentace
LC/MS, LC/MS/MS, LC/QQQ
Výrobce
Agilent Technologies
Zaměření
Potraviny a zemědělství

PFAS in Biota: Risk Context & Robust Analytical Solutions

Ostatní
| 2026 | ALS Europe
Instrumentace
Laboratorní rozbory, LC/MS, LC/MS/MS
Výrobce
Zaměření
Životní prostředí
Další projekty
GCMS
ICPMS
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.