LCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.
Pořadatel
Waters Corporation
Waters Corporation
Firmu Waters založil v roce 1958 pan James Waters. Od té doby se společnost Waters specializuje na kapalinovou chromatografii a hmotnostní spektrometrii. Divize TA Instruments působí na poli termální analýzy. V České republice je Waters zastoupen přímou pobočkou, která sídlí v Praze.
Tagy
LC/MS
LC/MS/MS
LC/QQQ
LinkedIn Logo

A complete workflow for the determination of drugs in hair - Forensics Webinar Week

ZÁZNAM | Proběhlo Pá, 16.10.2020
Byly vyvinuty dvě metody ACQUITY I-Class/Xevo TQ-S micro LC/MS/MS. Jedena pro měření 29 „základních drog“ a druhá pro měření THC, kanabidiolu a kanabinolu ve vlasech.
Přejít na webinář
Pixabay/Ryan McGuire: A complete workflow for the determination of drugs in hair - Forensics Webinar Week
Pixabay/Ryan McGuire: A complete workflow for the determination of drugs in hair - Forensics Webinar Week

The use of hair as a biological matrix for forensic toxicology testing has increased in popularity over the last decade, with laboratories testing for a panel of drugs as recommended by societies such as the Society of Hair Testing (SoHT) or the European Workplace Drug Testing Society (EWDTS).1-2

A robust sample preparation workflow and sensitive UPLC/MS/MS method has been developed that allows the user to determine such panels of drugs of abuse in hair to meet these guidelines. The workflow allows the user to determine multiple classes of drugs such as opiates, amphetamines, cocaine, ketamine, buprenorphine, benzodiazepines and their metabolites as well as tetrahydrocannabinol (THC) and its metabolite carboxy-THC (cTHC) from a single hair specimen.

Following incubation in a commercially available extraction buffer, the analytes were separated from the remaining hair matrix using a single solid phase extraction (SPE) method using OASIS PRiME MCX 96-well plates. Two ACQUITY I-Class / Xevo TQ-S micro LC/MS/MS methods were developed; one to measure 29 “basic drugs” and the second to measure THC, cannabidiol and cannabinol.

This workflow allows all the analytes to be quantified at concentrations below the recommended confirmation cut-offs of the two societies in under 10 minutes per sample, allowing for a large number of samples to be analysed in a short period of time.

Presenter: Robert Lee (Principal Clinical Application Scientist, Waters Corporation)

Rob Lee is a Principal Application Scientist in the Toxicology group in the Waters Scientific Operations Group.

Rob has published many papers on the analysis of toxicologically relevant small molecules in biological matrices. He is a recognized expert in the use of liquid chromatography with mass spectrometry, giving invited papers at international meetings around the world.

After obtaining an honours degree in Bioanalytical Sciences from Kingston Polytechnic, London in 1987, he started work at Biorex Research Laboratories in the Drug Metabolism Department. During his time at Biorex he conducted many in vivo drug metabolism studies. In 1989 he moved to BIBRA laboratories where he was responsible for developing methods for the determination of DNA adducts in mouse skin following exposure to various mineral oils. In 1994 he moved to Zeneca, later Syngenta, where he undertook work into the comparative mechanisms of toxicity of various industrial and agrochemical materials in different animal species. In 2007 he started working for Waters Corporation in the Toxicology Group in the Clinical Business Operations group. He has developed many methods for the analysis of toxicologically relevant compounds in various biological matrices and presented these methods at international meetings around the world.

Waters Corporation
LinkedIn Logo
 

Mohlo by Vás zajímat

Benefits of Agilent Altura Ultra Inert HPLC Column Hardware

Aplikace
| 2026 | Agilent Technologies
Instrumentace
Spotřební materiál, LC kolony
Výrobce
Agilent Technologies
Zaměření
Životní prostředí

Vinylene carbonate water determination via coulometric Karl Fischer titration

Aplikace
| 2026 | Metrohm
Instrumentace
Titrace Karl Fischer, Voltametrie/Coulometrie
Výrobce
Metrohm
Zaměření
Polovodiče

An Isocratic Separation of B Vitamins Using Waters XBridge Biphenyl RP Column with MaxPeak Premier Technology

Aplikace
| 2026 | Waters
Instrumentace
Spotřební materiál, LC kolony
Výrobce
Waters
Zaměření
Farmaceutická analýza

Impurity Monitoring of GLP-1 Therapeutic Peptide RetatrutideUsing a 2D-LC/TOF System

Postery
| 2026 | Agilent Technologies (ASMS)
Instrumentace
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS, 2D-LC
Výrobce
Agilent Technologies
Zaměření
Farmaceutická analýza

Increased sensitivity for low-input label-free proteomics using the Orbitrap Astral MS and μPAC Neo Plus Columns

Aplikace
| 2026 | Thermo Fisher Scientific
Instrumentace
LC/HRMS, LC/Orbitrap, LC/MS, LC/MS/MS
Výrobce
Thermo Fisher Scientific
Zaměření
Proteomika
Další projekty
GCMS
ICPMS
Sledujte nás
FacebookX (Twitter)LinkedInYouTube
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.