LCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.
Pořadatel
Waters Corporation
Firmu Waters založil v roce 1958 pan James Waters. Od té doby se společnost Waters specializuje na kapalinovou chromatografii a hmotnostní spektrometrii. Divize TA Instruments působí na poli termální analýzy. V České republice je Waters zastoupen přímou pobočkou, která sídlí v Praze.
Tagy
HPLC
Logo of LinkedIn

All about dn/dc values and concentration detectors (UV and RI) for MALS

ZÁZNAM | Proběhlo Pá, 12.4.2024
Vše o hodnotách dn/dc a detektorech koncentrace (UV a RI) pro MALS
Přejít na webinář
Waters Corporation: All about dn/dc values and concentration detectors (UV and RI) for MALS

Waters Corporation: All about dn/dc values and concentration detectors (UV and RI) for MALS

Live Interactive Web Series

We’ll work through a topic of the week (roughly 60 minutes) and discuss any questions that come up along the way. During these sessions, we’ll talk about how to care for your SEC-MALS or FFF-MALS system, help you brush up on your ASTRA and DYNAMICS data processing, discuss measuring dn/dc values and why dn/dc is important, and see how stable RI baselines are achievable.

Working with polydisperse samples? We’ll see how to leverage ASTRA’s distribution analysis and results fitting features. Special topics on error analysis, batch MALS work, and more.

The live interactive web series are 100% live sessions, with anonymous Q&A welcome during and after the discussion. Free for all to attend.

  • Part 1 of 6: Why we love Multi-Angle Light Scattering! How MALS works and what it measures. Modes of operation and when to use them*

    • MALS theory and operating principles
    • Batch MALS vs. flow mode MALS: when and why
    • What MALS can and cannot measure directly
  • Part 2 of 6: Getting to know your MALS hardware, including ‘proper care & feeding’ of the system, practical guides for optimizing data quality, and how to know when your DAWN hardware needs special attention*

    • Understanding the MALS hardware internal and external components
    • Diagnosing hardware issues
    • How to help your MALS operate at its best
  • Part 3 of 6: Let it flow - Leveraging MALS with Size Exclusion Chromatography SEC / Gel Permeation Chromatography GPC. Considerations for successful SEC-MALS / GPC-MALS operation. How to process ASTRA data on and after day 1*

    • Practical considerations for MALS in SEC/GPC mode
    • Understanding system settings & coefficients such as inter-detector band broadening and normalization
    • Squeezing the most information from your SEC-MALS data
  • Part 4 of 6: Advanced topics in ASTRA data analysis - uncertainty calculations, MW averages, mass recovery, distribution analysis, results fitting, and data exporting*

    • Understanding the ways ASTRA tracks and calculates system errors
    • Leveraging peak integration to understand what’s in your sample
    • When and why to use the various MW averages: Mn, Mw, Mz, Mp, Mavg, Mv, etc.
    • Efficient and easy ways to export exactly the data and results you want, right out of ASTRA
  • Part 5 of 6: All about dn/dc values and concentration detectors (UV and RI) for MALS*

    • Understanding dn/dc, what it is, and how it is used with MALS
    • Measuring / determining dn/dc for your samples
    • UV detectors and their role in MALS
    • Mass recovery in ASTRA
  • Part 6 of 6: MALS flow cell care: diagnosing and cleaning your flow cell*

    • How to avoid the need to clean your MALS flow cell in the first place
    • How to diagnose a dirty MALS flow cell
    • How to take apart and clean your MALS flow cell

*It is recommended but not required that you attend all the sessions in this series.

Presenter: Dr. Andy Meyer

Dr. Andy Meyer joined Wyatt Technology in 2001, serving for several years as an Applications Scientist, then as Dean of Wyatt's "Light Scattering University" and as Director of Customer Service & Support. After managing multiple regions in North America, Dr. Meyer is now a Senior Application Scientist for Wyatt. As a Wyatt customer, he completed his Ph.D. in Applied Science – Polymer Chemistry from the College of William and Mary in Virginia.

Waters Corporation
 

Mohlo by Vás zajímat

IMPACT OF HPLC INSTRUMENTATION ON NON- SPECIFIC ADSORPTION OF PEPTIDES

Postery
| 2024 | Waters (Analytica)
Instrumentace
HPLC
Výrobce
Waters
Zaměření
Proteomika

Determination of Nitrosamine Impurities and NDSRI in Anti-diabetic Drugs on Shimadzu LCMS-8060NX

Aplikace
| 2024 | Shimadzu
Instrumentace
LC/MS, LC/MS/MS, LC/QQQ
Výrobce
Shimadzu
Zaměření
Farmaceutická analýza

Ochrana zdrojů pitných vod: Inovativní řešení problematiky výskytu pesticidů v krajině

Ostatní
| 2024 | ALS Czech Republic
Instrumentace
LC/MS, GC/MSD
Výrobce
Zaměření
Životní prostředí

An advanced integrated GC-MS/MS and LC-MS/MS workflow for the comprehensive analysis of pesticide residues in food

Aplikace
| 2024 | Thermo Fisher Scientific
Instrumentace
GC/MSD, GC/MS/MS, GC/QQQ, LC/MS, LC/MS/MS, LC/QQQ
Výrobce
Thermo Fisher Scientific
Zaměření
Potraviny a zemědělství

Method Modernization and Method Development (e-Book)

Příručky
| 2024 | Thermo Fisher Scientific
Instrumentace
HPLC
Výrobce
Thermo Fisher Scientific
Zaměření
Ostatní
Další projekty
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.