LCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.
Pořadatel
Shimadzu Corporation
Shimadzu Corporation
Společnost Shimadzu vyrábí nejširší sortiment přístrojů pro instrumentální analytiku, testování materiálů a life science.
Tagy
LC/MS
LC/MS/MS
LC/TOF
LC/HRMS
LinkedIn Logo

Understand the rationale behind the Q-TOF LC/MS that stably sustains sub-ppm mass accuracy.

ZÁZNAM | Proběhlo Út, 27.11.2018
Různé metriky, které jsou důležité pro statistickou interpretaci MMA a které vysvětlují, proč je hmotnostní rozlišení 30 000 více než dostatečné pro měření hmotnosti.
Přejít na webinář
Shimadzu: Understand the rationale behind the Q-TOF LC/MS that stably sustains sub-ppm mass accuracy.
Shimadzu: Understand the rationale behind the Q-TOF LC/MS that stably sustains sub-ppm mass accuracy.

High-resolution, accurate-mass (HRAM) mass spectrometers (MS) are a class of MS instrumentation with capability to resolve complex sample matrix and to allow identification of compounds by measuring their accurate masses.

In particular, those coupled to liquid chromatograph (HRAM LC/MS) have been used extensively for structural elucidation of unknown compounds primarily in chemical industry (impurity analysis) and biological researches (proteomics, metabolomics, lipidomics), but also increasingly in forensic science, food safety and environmental testing. Given the recent reduction of instrumentational cost, it will not take many more years until HRAM analysis becomes a versatile tool for all industries and researches.

The key performance attribute underlying all application fields is mass measurement accuracy (MMA) as it affords molecular specificity and reduction of false positive results. MMA is given in the specification of HRAM instruments in parts-per-million (ppm), frequently stating a result of a set of representative measurements e.g. “<1 ppm RMS”. However, this by itself does not convey how repeatably and reproducibly this MMA can be achieved.

The webinar describes various metrics that are relevant to statistical interpretation of MMA, which explain why mass resolution of 30,000 is more than sufficient for mass measurement at sub-ppm accuracy. Using the Shimadzu LCMS-9030 quadrupole time-of-flight MS, the rationale and strength of instrument stability for consistently achieving sub-ppm MMA has been demonstrated in small molecules.

Learning objectives:

Discuss how various parameters affect the accuracy of mass measurement
Demonstration of mass drift caused by temperature change
Learn how to assess whether a HRAM MS is practically capable of measuring at sub-ppm mass accuracy

Presenter: Atsuhiko (Ash) Toyama, PhD (MS Application Specialist, Analytical & Measuring Instruments Division, Shimadzu Corporation)

Ash Toyama has 10 years of proteomics research experience. His areas of expertise include not only proteomics but also quantitative mass spectrometry with particular focus on bioanalysis, metabolomics and endocrinology. At Shimadzu Corporation he played roles in academic research collaborations, application development and specification development of mass spectrometers. Ash holds a Master of Science degree in Biochemistry from University of Cambridge, UK, and was granted a Ph.D. degree in Biological Sciences from University of Tokyo for his research on clinical proteomics.

Shimadzu Corporation
LinkedIn Logo
 

Mohlo by Vás zajímat

Overcoming Strong Solvent Effects in the Analysis of Vepdegestrant

Aplikace
| 2026 | Agilent Technologies
Instrumentace
HPLC
Výrobce
Agilent Technologies
Zaměření
Farmaceutická analýza

Identification of Double Bond Positions and Relative Acyl Chain Positions in Egg Yolk Phosphatidylcholines Using OAD-TOF System

Aplikace
| 2026 | Shimadzu
Instrumentace
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS
Výrobce
Shimadzu
Zaměření
Potraviny a zemědělství

High Molecular-Weight Polysaccharide Characterization by SEC-MALS Using GTxResolve™ 1000 and 2000 Å SEC Columns

Aplikace
| 2026 | Waters
Instrumentace
GPC/SEC, Spotřební materiál, LC kolony
Výrobce
Waters
Zaměření
Farmaceutická analýza, Potraviny a zemědělství

Development and Optimization for a Comprehensive LC/MS/MS Method for the Detection of 74 PFAS Compounds

Aplikace
| 2026 | Agilent Technologies
Instrumentace
LC/MS, LC/MS/MS, LC/QQQ
Výrobce
Agilent Technologies
Zaměření
Potraviny a zemědělství

PFAS in Biota: Risk Context & Robust Analytical Solutions

Ostatní
| 2026 | ALS Europe
Instrumentace
Laboratorní rozbory, LC/MS, LC/MS/MS
Výrobce
Zaměření
Životní prostředí
Další projekty
GCMS
ICPMS
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.