LCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.
Pořadatel
Separation Science
Separation Science je přední online zdroj metod, aplikací, řešení problémů a školení v chromatografii a hmotnostní spektrometrii.
Tagy
LC/MS
HPLC
LC/Orbitrap
LC/HRMS
Logo of LinkedIn

Practical strategies to decrease uncertainty in comprehensive extractables and leachables analysis by LC/MS

ZÁZNAM | Proběhlo Pá, 2.6.2023
Budeme diskutovat o výzvách spojených s těmito analýzami a představíme strategie, které lze použít ke snížení nejistoty ve studiích extrahovatelných LC/MS.
Přejít na webinář
Pixabay/Jan Felix Christiansen: Practical strategies to decrease uncertainty in comprehensive extractables and leachables analysis by LC/MS

Pixabay/Jan Felix Christiansen: Practical strategies to decrease uncertainty in comprehensive extractables and leachables analysis by LC/MS

In extractables studies, LC/UV/MS is commonly used to detect and annotate the non-volatile fraction of compounds. Industry guidance and regulatory requirements indicate an analytical evaluation threshold (AET), above which compounds need to be identified to allow for toxicological risk assessment, requiring estimated quantitation before their identity is known. UV and MS detector response is known to vary for analytes, requiring the use of an uncertainty factor to account for difference in response relative to a reference standard at the AET.

In this webinar, we will discuss the challenges associated with these analyses and present strategies that can be deployed to reduce uncertainty in LC/MS extractable studies, including the combination of the three detection techniques in one system to allow the concurrent measurement of UV absorption, CAD signal, and high resolution-accurate mass (HRAM) mass spectra from one injection.

By attending this presentation you will learn about:
  • Ways to decrease analytical uncertainty in quantitation of unknown extractables by LC/MS
  • How incorporating UV, CAD, and MS in one system provides orthogonal detection based on different properties, increasing compound coverage and annotation confidence
  • How the universal response of the CAD detector, when used with the Vanquish Duo for inverse gradient system, enables semi-quantitation of unknown compounds against surrogate standards with lower uncertainty

Presenter: Chongming Liu

Chongming Liu is currently a Supervisor in the Extractables and Leachables (E&L) team at SGS Health Science in Fairfield, New Jersey, USA. At SGS, his daily responsibility is to assist the team members in performing E&L testing on pharmaceutical containers and medical devices and to elucidate structures for compounds of interest based on high-resolution GC-FID/MS and LC-PDA/MS data. Prior to that, he joined the E&L team at SGS in 2018 as an Instrumentation Chemist. Chongming holds a PhD degree in Analytical Chemistry from Stevens Institute of Technology, in Hoboken, New Jersey and a BSc degree in Chemistry from the University of Science and Technology of China (USTC), in Hefei, China.

Presenter: Sven Hackbusch

Sven Hackbusch is currently a Senior Application Scientist at Thermo Fisher Scientific, responsible for the development of LC/MS applications related to structural elucidation for and in collaboration with customers in the Pharma/Biopharma markets. He joined Thermo Fisher Scientific in 2017 as an Application Scientist in the LC/MS product demonstration laboratory, focusing on untargeted small molecule applications using Thermo Scientific Orbitrap technology. Sven holds a PhD in Pharmaceutical and Chemical Sciences from the University of the Pacific in Stockton, California, USA and a BSc in Chemistry from the Justus Liebig Universität Gießen in Gießen, Germany.

Separation Science
 

Mohlo by Vás zajímat

Deeper proteome coverage and faster throughput for single-cell samples on the Orbitrap Astral mass spectrometer

Technické články
| 2024 | Thermo Fisher Scientific
Instrumentace
LC/Orbitrap, LC/HRMS, LC/MS/MS, LC/MS
Výrobce
Thermo Fisher Scientific
Zaměření
Proteomika

Purity quantification of tris(hydroxymethyl)aminomethane (TRIS) with IC

Aplikace
| 2024 | Metrohm
Instrumentace
Iontová chromatografie
Výrobce
Metrohm
Zaměření
Farmaceutická analýza, Klinická analýza

Quantitation of N-Nitroso-Propranolol in Drug Substance using LC-MS/MS

Aplikace
| 2024 | Waters
Instrumentace
LC/MS, LC/MS/MS, LC/QQQ
Výrobce
Waters
Zaměření
Farmaceutická analýza

Analysis of PFAS by EPA Methods 533, 537.1, and 8327

Příručky
| 2024 | Agilent Technologies
Instrumentace
Standardy
Výrobce
Agilent Technologies
Zaměření
Životní prostředí

DMT-on Purification of Phosphorothioate Oligonucleotide Using SHIMSEN Styra HLB SPE Cartridge

Aplikace
| 2024 | Shimadzu
Instrumentace
Příprava vzorků, Spotřební materiál, HPLC
Výrobce
Shimadzu
Zaměření
Proteomika
Další projekty
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.