LCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.
Pořadatel
Agilent Technologies
Agilent Technologies
Analytičtí vědci a kliničtí výzkumníci po celém světě spoléhají na Agilent a na to, že jim pomůže splnit i ty nejsložitější požadavky v laboratoři. Naše přístroje, software, služby a spotřební materiál řeší celou škálu potřeb ve Vaší laboratoři.
Tagy
LC/MS
LC/MS/MS
LC/TOF
LC/HRMS
LC/QQQ
Akademie/Principy
LinkedIn Logo

How to set MS Scan Parameters for your LCMS Experiment

ZÁZNAM | Proběhlo St, 26.4.2023
Bude prezentován snadno následovatelný průvodce, který podrobně popisuje, jak nastavit parametry MS skenování pro LCMS experiment.
Přejít na webinář
Agilent Technologies: How to set MS Scan Parameters for your LCMS Experiment
Agilent Technologies: How to set MS Scan Parameters for your LCMS Experiment
  • Wait what?! Who knew!? There are so many things that a mass spec can do.

  • I've used it for years, yes this may be true.

  • I've processed some samples, more than a few.

  • But between me and you, I had no idea all the things it could do!

  • From sample prep to separation, you just won't believe…

  • All of the tips and tricks we have up our sleeve.

  • So, take a few minutes, about 15 should do.

  • And learn all the things your mass spec can do.

An easy to follow guide detailing how to set MS scan parameters for an LCMS experiment will be presented. Scan speeds for reproducible quantitation, chromatographic resolution, retention time definition, proper threshold adjustment for optimum datafile size, and how this can result in faster processing times will all be discussed.

Presenter: Rebecca Glaskin, Ph.D. (LC/MS Application Scientist, Agilent Technologies, Inc.)

Rebecca Glaskin is an LC/MS Application Scientist at Agilent with a focus on BioPharma applications supporting the LC-Q/TOF and IM-QTOF platforms. Prior to joining Agilent, Rebecca received her Ph.D. in analytical chemistry from Indiana University in the lab of Professor David Clemmer. While there she designed and constructed home-built instruments, pushing the limits of the mobility resolution that can be obtained with a circular drift tube for the separation of biomolecules (peptides, proteins, carbohydrates, and metabolites). While there, she also studied hydrogen/deuterium exchange of proteins in the gas-phase as a function of time and pressure. Rebecca then went to Boston University as a Postdoctoral Associate in the lab of Professor Catherine Costello to develop a database containing collision cross section values for glycans, peptides, and glycopeptides utilizing Agilent Technologies 6560 IM-QTOF. This database can be used to determine how the collision cross section is altered with the addition of individual saccharide units. The trendlines obtained from this database will be used to predict collision cross sections for glycopeptides based on the conformation and structure of the specific glycoform.

Presenter: Jim Lau, PhD (HRAMS LC/MS Application Engineer, Agilent Technologies, Inc.)

Jim Lau received his Ph.D. From the University of Colorado. There he worked in the laboratories of Peter Albersheim and Robert Shapiro. This work involved the structure elucidation of plant natural products and, in particular, elucidating the structures of oligosaccharides derived from plant cell wall polysaccharides. This work was done in the early days of LCMS and made use of DLI-LCMS and (at the time) recently invented Thermospray-LCMS.

After the completion of his Ph.D., Jim joined Hewlett-Packard to work on LCMS ionization techniques with Paul Goodley during the early days of Electrospray-LCMS. He then moved to work on field applications and collaborations with Hewlett-Packard’s LCMS customers. More than 30 years later, Jim continues to work with Agilent’s customers in High Resolution Accurate Mass applications of LCMS. While involved in many areas of HRAMS LCMS, his recent work has focused on the area of Screening/Qual&Quant of small molecules and on the high throughput confirmation of oligonucleotide synthesis.

Agilent Technologies
LinkedIn Logo
 

Mohlo by Vás zajímat

Determination of Authenticity of Manuka Honey Using the MALDI-8030 Benchtop Linear MALDI-TOF Mass Spectrometer

Aplikace
| 2026 | Shimadzu
Instrumentace
MALDI, LC/MS, LC/TOF
Výrobce
Shimadzu
Zaměření
Potraviny a zemědělství

Analysis of Inorganic Anions in Drinking Water According to EPA Method 300.1 Using Nexera IC -Part A

Aplikace
| 2026 | Shimadzu
Instrumentace
Iontová chromatografie
Výrobce
Shimadzu
Zaměření
Potraviny a zemědělství

Quality Evaluation of mRNA by Electrophoresis

Aplikace
| 2026 | Shimadzu
Instrumentace
Kapilární elektroforéza
Výrobce
Shimadzu
Zaměření
Farmaceutická analýza

LC/MS dMRM Method Refinement Expands Targeted Lipidomics Studies from Plasma to Cells and Tissues

Aplikace
| 2026 | Agilent Technologies
Instrumentace
LC/MS, LC/MS/MS, LC/QQQ
Výrobce
Agilent Technologies
Zaměření
Lipidomika, Klinická analýza

Sensitive Detection of Aflatoxins by the Agilent 1290 Infinity III Fluorescence Detector

Aplikace
| 2026 | Agilent Technologies
Instrumentace
HPLC
Výrobce
Agilent Technologies
Zaměření
Potraviny a zemědělství
Další projekty
GCMS
ICPMS
Sledujte nás
FacebookX (Twitter)LinkedInYouTube
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.