LCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.
Pořadatel
Separation Science
Separation Science
Separation Science je přední online zdroj metod, aplikací, řešení problémů a školení v chromatografii a hmotnostní spektrometrii.
Tagy
IC
LinkedIn Logo

Determination of Inorganic Anions and Organic Acids in Lithium-Borated Nuclear Power Plant Waters using Ion Chromatography

ZÁZNAM | Proběhlo St, 23.3.2022
Iontová chromatografie s detekcí s vodivostní detekcí se supresí je vhodnou metodou pro stanovení aniontů a kationtů včetně přechodných kovů ve vodách elektráren v µg/l (ppb) i mg/l (ppm).
Přejít na webinář
Pixabay/Markus Distelrath: Determination of Inorganic Anions and Organic Acids in Lithium-Borated Nuclear Power Plant Waters using Ion Chromatography
Pixabay/Markus Distelrath: Determination of Inorganic Anions and Organic Acids in Lithium-Borated Nuclear Power Plant Waters using Ion Chromatography

Separation Science, in collaboration with Thermo Fisher Scientific, offers an upcoming webinar demonstrating how ion chromatography with suppressed conductivity detection is the safe and reliable method of choice to determine both µg/L (ppb) and mg/L (ppm) levels of anions and cations including transition metals in power plant waters.

Successful operation of a nuclear power plant (NPP) demands careful control and monitoring of water chemistry in primary coolant dosed with boron and lithium, steam generator tubes dosed with ammonia, closed cooling water systems dosed with nitrite and other structural parts that are subject to corrosion and crud deposition. This can affect plant operation and radiation exposure during refueling downtime.

Ion chromatography is the safe and reliable method of choice to determine both µg/L (ppb) and mg/L (ppm) levels of anions and cations including transition metals in power plant waters. Cation-exchange chromatography with non-suppressed conductivity detection is a simple and direct technique for quantifying low-µg/L concentrations of selected transition metals.

Lithium-borated water, and ammoniated condensate, is measured for low-level µg/L concentrations of fluoride, chloride, and sulfate with the addition of a continuously regenerated cation trap column (CR-CTC) to remove interference from mg/L concentrations of either lithium or ammonia in the samples. Other closed cooling water systems are dosed with high nitrite concentrations (up to 1000 mg/L) to prevent corrosion, but low-level µg/L chloride measurement is required for early signs of seawater ingress. This is possible with a Thermo Scientific™ Dionex™ AS14A Eluent Concentrate; (Sodium Carbonate/Bicarbonate Concentrate).

By attending this webinar you will learn:

  • how the new Thermo Scientific™ Dionex™ CR-TC Continuously Regenerated Trap Column (CR-CTC III) removes interference from mg/L concentration of either lithium or ammonia in samples
  • how ion chromatography with suppressed conductivity detection is the safe and reliable method of choice to determine both µg/L (ppb) and mg/L (ppm) levels of anions and cations including transition metals in power plant waters.

Presenter: Peter O’Brien (Systems Engineer, EDF Energy, UK)

Peter O’Brien has been a chemist at Sizewell B Nuclear Power Plant since 2006. He joined as a chemistry apprentice and graduated as a shift chemistry technician before progressing into the position of Chemistry Lab Team Leader. While an apprentice, a chemist with over 40 years of lab experience mentored him and, together, they were the ion chromatography specialists at the time. When the chemist retired in 2008, Peter took over the specialist role. To-date, he has accrued 16 years of experience with ion chromatography at a nuclear power plant.

Peter’s achievements to date include working with Thermo Fisher Scientific to move lithium and sodium determination away from flame atomic absorption using unstable explosive acetylene to a far safer method using liquid ion chromatography, and improving levels of precision and accuracy measuring sub-µg/L concentrations of primary coolant and feed water anion and cations. This has been achieved through the addition of continuously regenerated cation trap columns (CR-CTC) with the company's sample preparation. The next goal is to further improve sub- µg/L limit of detection using an autosampler to enhance sample preparation and dilution.

Separation Science
LinkedIn Logo
 

Mohlo by Vás zajímat

Overcoming Strong Solvent Effects in the Analysis of Vepdegestrant

Aplikace
| 2026 | Agilent Technologies
Instrumentace
HPLC
Výrobce
Agilent Technologies
Zaměření
Farmaceutická analýza

Identification of Double Bond Positions and Relative Acyl Chain Positions in Egg Yolk Phosphatidylcholines Using OAD-TOF System

Aplikace
| 2026 | Shimadzu
Instrumentace
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS
Výrobce
Shimadzu
Zaměření
Potraviny a zemědělství

High Molecular-Weight Polysaccharide Characterization by SEC-MALS Using GTxResolve™ 1000 and 2000 Å SEC Columns

Aplikace
| 2026 | Waters
Instrumentace
GPC/SEC, Spotřební materiál, LC kolony
Výrobce
Waters
Zaměření
Farmaceutická analýza, Potraviny a zemědělství

Development and Optimization for a Comprehensive LC/MS/MS Method for the Detection of 74 PFAS Compounds

Aplikace
| 2026 | Agilent Technologies
Instrumentace
LC/MS, LC/MS/MS, LC/QQQ
Výrobce
Agilent Technologies
Zaměření
Potraviny a zemědělství

PFAS in Biota: Risk Context & Robust Analytical Solutions

Ostatní
| 2026 | ALS Europe
Instrumentace
Laboratorní rozbory, LC/MS, LC/MS/MS
Výrobce
Zaměření
Životní prostředí
Další projekty
GCMS
ICPMS
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.