Performance Characteristics of the Agilent 1260 Infinity II LC System – an Entry System for Routine Analysis
Technické články | 2020 | Agilent TechnologiesInstrumentace
HPLC
ZaměřeníVýrobceAgilent Technologies
Klíčová slovarsd, phthalate, caffeine, mau, area, gradient, parameter, injection, value, paraben, solvent, sample, rate, propiophenone, octanophenone, temperature, heptanophenone, butyrophenone, terphenyl, acetanilide, chlorhexidine, hexanophenone, rrlc, seven, detection, valerophenone, column, min, flow, heptylparaben, diethyl, benzophenone, acetophenone, uracil, checkout, time, water, acetonitrile, linearity, biphenyl, system, phenol, agilent, compound, analyte, dimethyl, isocratic, suitability, enterprise, amitriptyline
Podobná PDF
Performance Characteristics of the Agilent 1290 Infinity II Vialsampler
2015|Agilent Technologies|Technické články
Performance Characteristics of the Agilent 1290 Infinity II Vialsampler Technical Overview Author Abstract Melanie Metzlaff This Technical Overview describes the features and performance of the Agilent Technologies, Inc. Agilent 1290 Infinity II Vialsampler. With a power range up to 1,300…
Klíčová slova
rsd, rsdinjection, injectionchlorhexidine, chlorhexidineoctanophenone, octanophenonepropiophenone, propiophenonearea, areaheptanophenone, heptanophenonebutyrophenone, butyrophenonehexanophenone, hexanophenoneacetanilide, acetanilidevalerophenone, valerophenonemau, mauvialsampler, vialsampleracetophenone, acetophenonephthalate
Performance Characteristics of the Agilent 1260 Infinity II Bio-Inert LC
2017|Agilent Technologies|Technické články
Performance Characteristics of the Agilent 1260 Infinity II Bio-Inert LC Technical Overview Authors Introduction Sonja Schneider and Uschi Schweikert The Agilent 1260 Infinity II Bio-inert LC is the next generation of Agilent Bio-inert LC, specially designed for conditions used in…
Klíčová slova
mau, maudad, dadtime, timeflow, flowstop, stopcell, cellbio, biomin, minwidth, widthinert, inertpeak, peakparaben, parabenmobile, mobilechromatographic, chromatographiccolumn
Performance Characteristics of the Agilent 1260 Infinity II Hybrid Multisampler
2023|Agilent Technologies|Technické články
Technical Overview Performance Characteristics of the Agilent 1260 Infinity II Hybrid Multisampler Introduction A typical sample introduction principle used for HPLC autosampler modules is the flow-through injection (Figure 1A). With this injection mode, the metering device, the loop, and the…
Klíčová slova
feed, feedinjection, injectionflow, flowthrough, throughdraw, drawcarryover, carryovervolume, volumechlorhexidine, chlorhexidinepump, pumpsolvent, solventtime, timeinjections, injectionsspeed, speedagilent, agilentpeak
Different Food Applications on a Single LC System Using Automated Column and Solvent Selection
2016|Agilent Technologies|Aplikace
Different Food Applications on a Single LC System Using Automated Column and Solvent Selection Agilent 1260 Infinity II Multimethod Solution Application Note Food Testing & Agriculture Author Abstract Sonja Krieger The Agilent 1260 Infinity II Multimethod solution facilitates running multiple…
Klíčová slova
mau, mauacesulfam, acesulfamchewing, chewingsalicylic, salicylicfacial, facialtonic, tonicaspartame, aspartamegum, gumacid, acidpreservatives, preservativesselection, selectionbha, bhaarea, areacolumn, columndrink