Analysis of Formamidine Pesticides and Metabolites in Pork and Porcine Liver Using Agilent Captiva EMR—Lipid and LC/MS/MS
Aplikace | 2019 | Agilent TechnologiesInstrumentace
Příprava vzorků, Spotřební materiál, LC/MS, LC/MS/MS, LC/QQQ
ZaměřeníPotraviny a zemědělství
VýrobceAgilent Technologies
Klíčová slovaamz, porcine, pork, liver, extraction, lipid, emr, cdm, blank, formamidine, captiva, quechers, rec, dcdm, dcmd, cleanup, acaricides, spiking, standard, agilent, analyte, matrix, cmd, were, counts, insects, pesticides, prespiked, min, acquisition, solvent, metabolites, pesticide, rsd, time, optimization, veterinary, using, standards, repellents, its, without, metabolite, validated, replicates, sheath, regent, sample, alta, xia
Podobná PDF
Analysis of Acetyl Progesterones in Pork, Eggs, and Milk Using the Agilent Captiva EMR—Lipid by LC/MS/MS
2020|Agilent Technologies|Aplikace
Application Brief Food Testing and Agriculture Analysis of Acetyl Progesterones in Pork, Eggs, and Milk Using the Agilent Captiva EMR—Lipid by LC/MS/MS Authors Cuiling Wu, Juan An, and Limian Zhao Agilent Technologies, Inc. Abstract This study developed and validated a…
Klíčová slova
fga, fgamga, mgacma, cmarec, recpos, poskidney, kidneypork, porkegg, eggagilent, agilentemr, emrcaptiva, captivaliver, livermilk, milkrsd, rsdlipid
Complex Matrices: Minimizing Lipids, Maximizing Recovery - Food Testing Application Compendium: Volume 3
2018|Agilent Technologies|Příručky
Complex Matrices: Minimizing Lipids, Maximizing Recovery Food Testing Application Compendium: Volume 3 Complex Samples Don’t Have to Complicate Your Analysis Reducing matrix interference is a must for maintaining sensitivity standards—particularly for multiresidue, multiclass analysis of food samples. Minimize interferences in…
Klíčová slova
emr, emrlipid, lipidcleanup, cleanupmatrix, matrixelut, elutbond, bondpositive, positiveremoval, removalavocado, avocadocounts, countspos, posenhanced, enhancedcaptiva, captivaagilent, agilentacquisition
Analysis of Multiclass Multiresidue Pesticides in Milk Using Agilent Captiva EMR—Lipid with LC/MS/MS and GC/MS/MS
2020|Agilent Technologies|Aplikace
Application Note Food Testing and Agriculture Analysis of Multiclass Multiresidue Pesticides in Milk Using Agilent Captiva EMR—Lipid with LC/MS/MS and GC/MS/MS Authors Xia Yang, Youjuan Zhang, and Zhiming Zhang Agilent Technologies, Inc. Abstract This application note describes the analysis of…
Klíčová slova
sulfone, sulfonemean, meanemr, emrfipronil, fipronilrecovery, recoveryrsd, rsdlipid, lipidcleanup, cleanupcaptiva, captivaphorate, phoratehch, hchfenamiphos, fenamiphosmethyl, methylterbufos, terbufossetting
Multiclass Multiresidue Veterinary Drug Analysis in Beef Using Agilent Captiva EMR—Lipid Cartridge Cleanup and LC/MS/MS
2017|Agilent Technologies|Aplikace
Application Note Food Testing Multiclass Multiresidue Veterinary Drug Analysis in Beef Using Agilent Captiva EMR—Lipid Cartridge Cleanup and LC/MS/MS Authors Abstract Limian Zhao and Derick Lucas Agilent Technologies, Inc. Agilent Captiva Enhanced Matrix Removal—Lipid (EMR—Lipid) cartridges are the second generation…
Klíčová slova
pos, poscleanup, cleanuplipid, lipidemr, emrcaptiva, captivalactam, lactamcartridge, cartridgebeef, beeftetracycline, tetracyclineextractives, extractivesneg, negmatrix, matrixlli, llihydrophobic, hydrophobicremoval