LC Column Troubleshooting - Isolating the Source of the Problem
Prezentace | 2013 | Agilent TechnologiesInstrumentace
Spotřební materiál, LC kolony
ZaměřeníVýrobceAgilent Technologies
Klíčová slovacolumn, tailing, min, mau, volume, mobile, fittings, peak, phase, plugged, peaks, time, frit, red, extra, confidentiality, void, green, problem, pressure, what, wrong, selectivity, broadening, dwell, efficiency, problems, without, change, label, fitting, cause, effect, filter, system, effects, contamination, troubleshoot, lot, flow, split, troubleshooting, inconsistent, proportioned, plates, retention, changes, alkylphenones, broad, detector
Podobná PDF
Taking the Trouble Out of TroubleshootingIs It the Column, Method, or Instrument
2016|Agilent Technologies|Prezentace
Taking the Trouble Out of Troubleshooting Is It the Column, Method, or Instrument Rita Steed September 29, 2016 Page 1 What Do We Troubleshoot Typical LC troubleshooting approach asks: – What’s wrong with my column? – What’s wrong with my…
Klíčová slova
column, columnmobile, mobilephase, phaseproblems, problemsfrit, fritmau, maupeaks, peakstailing, tailingplugged, pluggedfittings, fittingspressure, pressurepeak, peakmin, minshape, shapevolume
New To HPLC - Avoiding Beginner Pitfalls
2013|Agilent Technologies|Prezentace
New To HPLC Avoiding Beginner Pitfalls Rita Steed LC Columns Application Engineer April 24, 2013 Outline Instrument • Connections • Performance • Detector Column • Characteristics • Lifetime Method Conditions • Mobile phase • pH • Temperature…
Klíčová slova
beginner, beginnerpitfalls, pitfallsavoiding, avoidingrestricted, restrictedagilent, agilentcolumn, columnmobile, mobilemin, minphase, phasemau, maufittings, fittingsvolume, volumepitfall, pitfallyour, yourred
Optimization of HPLC Instrumentation for Use with Poroshell 120 Columns
2010|Agilent Technologies|Postery
Optimal Design For A Mass Spectrometer Vacuum-pump Cover that Optimization of HPLC Instrumentation for Use with Poroshell 120 Columns Poster Number 2080-9 Reduces Pump Noise and Facilitates Oil Changes William J. Long, Anne E. Mack, John W. Henderson Jr. Agilent…
Klíčová slova
fittings, fittingsmau, maugreen, greenred, redhertz, hertzvolume, volumecollection, collectionrate, ratemin, mintubing, tubingswaged, swagedefficiency, efficiencyflow, flowcolumn, columncell
The Chromatography Detective: Troubleshooting Tips & Tools for LC & LCMS
2018|Agilent Technologies|Prezentace
The Chromatography Detective: Troubleshooting Tips & Tools for LC & LCMS Rita Steed LC Columns Application Engineer January 31, 2018 What do you do when..... ➢ Your chromatography changes • Peak shape • Retention ➢ You can’t reproduce a method…
Klíčová slova
beginner, beginnerpitfalls, pitfallsavoiding, avoidingcolumn, columndwell, dwellvolume, volumemobile, mobilephase, phaseecv, ecvpeak, peakinstrument, instrumentshape, shapetailing, tailingretention, retentionconnections