LCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.

HRAM LC-MS method for the determination of nitrosamine impurities in drugs

Aplikace | 2020 | Thermo Fisher ScientificInstrumentace
LC/HRMS, LC/MS, LC/MS/MS, LC/Orbitrap
Zaměření
Farmaceutická analýza
Výrobce
Thermo Fisher Scientific
Klíčová slova
PDF verze ke stažení a čtení
 

Podobná PDF

Toggle
Reliable quantitation of 11 nitrosamine impurities in metformin drug products using Orbitrap Exploris 120 mass spectrometry
APPLICATION NOTE 000362 Reliable quantitation of 11 nitrosamine impurities in metformin drug products using Orbitrap Exploris 120 mass spectrometry Authors: Hao Yang,1 Jon Bardsley,2 Min Du,3 Thermo Fisher Scientific, San Jose, CA, US Thermo Fisher Scientific, Hemel Hempstead, UK 3…
Klíčová slova
metformin, metforminpositive, positivenmpa, nmpandma, ndmanitrosamine, nitrosaminendba, ndbanmba, nmbanmea, nmeanpyr, npyrnpip, npipneipa, neipandipa, ndipandpa, ndpandea, ndeadrug
Nitrosamine impurities analysis using Thermo Scientific™ Orbitrap Exploris™ 120 MS
Nitrosamine impurities analysis using Thermo Scientific™ Orbitrap Exploris™ 120 MS Hao Yang, Ph.D. Sr. Application Scientist Biopharma and Pharma Vertical Marketing The world leader in serving science 1 Application: Nitrosamine impurities analysis Liquid chromatography high resolution mass spectrometry (LC-HRMS) method…
Klíčová slova
excipient, excipientneat, neatnas, nashesi, hesiapci, apcindma, ndmandba, ndbaneipa, neipappm, ppmnmea, nmeanpyr, npyrnpip, npipndipa, ndipandpa, ndpalloq
Highly sensitive and robust LC-MS/MS solution for quantitation of nitrosamine impurities in metformin drug products
APPLICATION NOTE 74059 Highly sensitive and robust LC-MS/MS solution for quantitation of nitrosamine impurities in metformin drug products Authors: Hao Yang1, Edmund Moy1, Michael Volny1, Claudia Martins1, Min Du2, Wael Elmasri3, Tanya Tadey4 Thermo Fisher Scientific, San Jose, CA; Thermo…
Klíčová slova
nitrosamines, nitrosaminesnitrosamine, nitrosaminendma, ndmadrug, drugnmpa, nmpametformin, metforminndba, ndbandea, ndeanmba, nmbanmea, nmeanpyr, npyrneipa, neipandipa, ndipandpa, ndpaisotopes
Highly sensitive and robust LC-HRAM-MS method for simultaneous quantitation of sixteen nitrosamines in multiple drug products
Application note | 001657 Pharma Highly sensitive and robust LC-HRAM-MS method for simultaneous quantitation of sixteen nitrosamines in multiple drug products Goal Authors Krishna Mane , Venkatesh Chanukuppa , The aim of this study was to evaluate and report on…
Klíčová slova
prm, prmnipma, nipmannea, nneanitroso, nitrosonda, ndandpha, ndphanmpa, nmpanitrosamine, nitrosaminemetformin, metforminnmor, nmornmba, nmbanmea, nmeanpyr, npyrnpip, npipneipa