Signal, Noise, and Detection Limits in Mass Spectrometry

 

Podobná PDF

Toggle
Why use Signal-To-Noise as a Measure of MS Performance When it is Often Meaningless?
Why use Signal-To-Noise as a Measure of MS Performance When it is Often Meaningless? Technical Overview Authors Abstract Greg Wells, Harry Prest, and The signal-to-noise of a chromatographic peak determined from a single measurement Charles William Russ IV, has served…
Klíčová slova
noise, noisesnr, snrsignal, signaldetection, detectionperformance, performancemetric, metricanalyte, analytemerit, meritlimits, limitsguidelines, guidelinesinjections, injectionsidl, idlreplicate, replicatevariance, varianceestablishing
Why Instrument Detection Limit (IDL) is a Better Metric for Determining The Sensitivity of Triple Quadrupole LC/MS Systems
Why Instrument Detection Limit (IDL) is a Better Metric for Determining The Sensitivity of Triple Quadrupole LC/MS Systems Technical Overview Authors Introduction Na Pi Parra and Lester Taylor Assessing the sensitivity of LC/MS instruments has relied on comparison of signal-to-noise…
Klíčová slova
metric, metricidl, idlprecision, precisionyour, yourtriple, tripleyou, yousensitivity, sensitivityrepeatability, repeatabilitydeviation, deviationnoise, noiseparra, parralester, lesterconfirms, confirmslimit, limitsignal
Sensitivity and acquisition speed with triple quadrupole technology
Sensitivity and acquisition speed with triple quadrupole technology
2021|Thermo Fisher Scientific|Technické články
White paper | 000269 Mass spectrometry Sensitivity and acquisition speed with triple quadrupole technology What is important to determine effectiveness and how to effectively measure performance Authors Introduction Alan Atkins , Cristina Jacob , Charles Ultra-high performance liquid chromatography (UHPLC)…
Klíčová slova
srm, srmnoise, noisetriple, triplesensitivity, sensitivityquadrupole, quadrupoleimportant, importantacquisition, acquisitionsignal, signalmass, massscan, scansrms, srmsspectrometers, spectrometershaving, havinglimits, limitsrates
Impact of Dwell Time and Ion Flux on Multiple Reaction Ion Monitoring (MRM) Measurement Precision
Poster Reprint ASMS 2019 WP-444 Impact of Dwell Time and Ion Flux on Multiple Reaction Ion Monitoring (MRM) Measurement Precision Behrooz Zekavat, Charles Nichols, Anabel Fandino Agilent Technologies Inc., Santa Clara, CA Introduction Experimental Triple quadrupole mass spectrometers (TQ MSs)…
Klíčová slova
rsd, rsddwell, dwellflux, fluxion, ionidl, idlarea, areatime, timeimpact, impactval, valprecision, precisionions, ionspulse, pulsemrm, mrmpoisson, poissonsulfaguanadine