LCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.
Pořadatel
Separation Science
Separation Science
Separation Science je přední online zdroj metod, aplikací, řešení problémů a školení v chromatografii a hmotnostní spektrometrii.
Tagy
Příprava vzorků
LC/MS
LC/MS/MS
LinkedIn Logo

Perfecting Pcats – Developing a More Robust UHPLC-MS/MS Method for Plasma Catecholamines using Low Volume SPE

ZÁZNAM | Proběhlo Út, 11.5.2021
Tento webinář bude diskutovat o typických matricí krevní plazmy a efektů různých předúprav vzorků.
Přejít na webinář
Pixabay/Gerd Altmann: Perfecting Pcats – Developing a More Robust UHPLC-MS/MS Method for Plasma Catecholamines using Low Volume SPE
Pixabay/Gerd Altmann: Perfecting Pcats – Developing a More Robust UHPLC-MS/MS Method for Plasma Catecholamines using Low Volume SPE

Separation Science, in collaboration with Biotage, presents a webinar that will cover typical plasma matrices and the effects of different sample pre-treatments, as well as describing different strategies for analyte enrichment to maintain method LOQs, using manual and automated low volume elution SPE procedures.

Achieving desired sensitivity for plasma catecholamines by LC-MS/MS can be challenging compared to established techniques such as electrochemical detection. Low clinical reference intervals often necessitate highly sensitive MS instruments. Maximum sensitivity and accuracy requires the removal of matrix components that interfere with analysis or suppress MS response (particularly phospholipids). Sample preparation clean-up and concentration enables clinical reference intervals to be met without the need for cumbersome derivatization steps, even when low volume samples are used.

Catecholamines are small highly polar analytes and require careful attention to pre-treatment and processing conditions, particularly pH and ionic strength in order to maximize analyte recovery. Selection of plasma anticoagulant can also have a significant effect on analyte stability and matrix interferences.

This webinar will discuss typical plasma matrices and the effects of different sample pre-treatments. The importance of analyte and sorbent pH control will be discussed along with selection of suitable approaches to maximize removal of matrix interferences and enhance method robustness. The final section will cover different strategies for analyte enrichment to maintain method LOQs, using manual and automated low volume elution SPE procedures.

By viewing this webinar you will gain:

  • an understanding of the challenges that can be encountered in determining plasma catecholamines
  • an introduction to low volume sample preparation strategies to overcome the challenges presented by endogenous small polar target analytes in the development of LC-MS/MS assays

Presenter: Adam Senior (Biotage GB Limited)

Adam is an analytical chemist with over twenty years’ method development experience in diverse industries. He is a Senior Scientist in the Innovation and Development group, having joined Biotage in 2011. Adam is involved in the development and validation of LC-MS/MS sample preparation assays incorporating solid-phase extraction and supported liquid extraction.

Separation Science
LinkedIn Logo
 

Mohlo by Vás zajímat

Overcoming Strong Solvent Effects in the Analysis of Vepdegestrant

Aplikace
| 2026 | Agilent Technologies
Instrumentace
HPLC
Výrobce
Agilent Technologies
Zaměření
Farmaceutická analýza

Identification of Double Bond Positions and Relative Acyl Chain Positions in Egg Yolk Phosphatidylcholines Using OAD-TOF System

Aplikace
| 2026 | Shimadzu
Instrumentace
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS
Výrobce
Shimadzu
Zaměření
Potraviny a zemědělství

High Molecular-Weight Polysaccharide Characterization by SEC-MALS Using GTxResolve™ 1000 and 2000 Å SEC Columns

Aplikace
| 2026 | Waters
Instrumentace
GPC/SEC, Spotřební materiál, LC kolony
Výrobce
Waters
Zaměření
Farmaceutická analýza, Potraviny a zemědělství

Development and Optimization for a Comprehensive LC/MS/MS Method for the Detection of 74 PFAS Compounds

Aplikace
| 2026 | Agilent Technologies
Instrumentace
LC/MS, LC/MS/MS, LC/QQQ
Výrobce
Agilent Technologies
Zaměření
Potraviny a zemědělství

PFAS in Biota: Risk Context & Robust Analytical Solutions

Ostatní
| 2026 | ALS Europe
Instrumentace
Laboratorní rozbory, LC/MS, LC/MS/MS
Výrobce
Zaměření
Životní prostředí
Další projekty
GCMS
ICPMS
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.