Syringe Filter Filtration Efficiency and Impact on LC Column Life
Technické články | 2020 | Agilent TechnologiesInstrumentace
Spotřební materiál, HPLC, LC kolony
ZaměřeníFarmaceutická analýza
VýrobceAgilent Technologies
Klíčová slovafiltration, column, unfiltered, backpressure, syringe, particulates, captiva, premium, peakarea, efficiency, rrhd, filters, were, agilent, plasma, test, life, filter, superficially, latex, ptfe, cause, impact, porous, can, centrifuged, sample, run, ext, used, prevent, subsequently, filtered, hplc, bar, extract, solutions, pes, pressure, lifetime, frits, size, nylon, shut, bead, samples, tested, appropriate, zorbax, columns
Podobná PDF
Sample Filtration Impact on LC Column Lifetime
2013|Agilent Technologies|Postery
Sample Filtration Impact on LC Column Lifetime Pittcon 2013 Philadelphia, PA Poster 550-9P Limian Zhao, Agilent Technologies, 2850 Centerville Road, Wilmington, DE 19808 Introduction Chemicals and reagents: • Latex Bead LB3 (0.3 µm mean particle size) for 0.2 µm syringe…
Klíčová slova
filtration, filtrationcolumn, columnbackpressure, backpressureptfe, ptfefilters, filterssyringe, syringeext, extunfiltered, unfilteredbar, barpes, pesefficiency, efficiencycentrifuged, centrifugednylon, nylonlife, lifeplasma
Agilent Captiva sample preparation filtration portfolio
2019|Agilent Technologies|Brožury a specifikace
Filtration Makes All the Difference Agilent Captiva sample preparation filtration portfolio Did You Know… The First Part of Your Workflow Can Cause Unexpected Downtime and Sample Rerun? Your time is precious… and so are your samples. Filtering samples before analysis…
Klíčová slova
captiva, captivapolypropylene, polypropylenenylon, nylonfilter, filterlie, lieppt, pptyour, yourfiltration, filtrationpore, poreremoval, removalagilent, agilentprotein, proteinlipid, lipidpolyvinyldifluoride, polyvinyldifluorideprecipitation
Improving Laboratory Productivity by Preventing UHPLC and LC/MS System Downtime
2013|Agilent Technologies|Postery
Improving Laboratory Productivity by Preventing UHPLC and LC/MS System Downtime Agilent Technologies, Inc., 2850 Centerville Road, Wilmington, DE 19808 Advancements in liquid chromatography columns, such as those with sub 2 µm and superficially porous particles, and UHPLC and LC/MS instrumentation…
Klíčová slova
guard, guardmau, mauproductivity, productivitycolumn, columnsulfachloropyridazine, sulfachloropyridazineprevent, preventfiltration, filtrationsulfamethoxazole, sulfamethoxazoleparticulates, particulatespreventing, preventingmin, minzorbax, zorbaxdowntime, downtimeanalytical, analyticaluhplc
Agilent Captiva syringe filters
2019|Agilent Technologies|Brožury a specifikace
Maximize the Accuracy of Your Results with Minimal Time and Effort Agilent Captiva syringe filters Captiva syringe filters are designed to give you: – Greater productivity The unique design produces the industry’s fastest flow rates. – High loading capacity They…
Klíčová slova
polypropylene, polypropylenenylon, nylonmbs, mbsmicrofiber, microfibercaptiva, captivasupplier, supplierpes, peshousing, housingcellulose, cellulosepore, poreptfe, ptfefilters, filtersagilent, agilentdiameter, diametercertification