Quantitation of cyanotoxins in drinking water according to EPA 544 guidelines
Aplikace | 2017 | Thermo Fisher ScientificInstrumentace
LC/MS, LC/MS/MS, LC/QQQ
ZaměřeníŽivotní prostředí
VýrobceThermo Fisher Scientific
Klíčová slovanodularin, mrl, pir, quantis, positive, drinking, microcystins, tsq, demonstration, water, triple, analyte, actual, rec, quadrupole, capability, rsd, initial, solid, lfsmd, hrpir, lfsm, epa, reporting, cyanotoxins, blooms, minimum, algal, liquid, spe, phase, toxin, spiked, spectra, average, requirements, quantitation, evaluations, thermo, spikes, times, lower, recovery, dev, dryness, mass, gas, scientific, were, vaporizer
Podobná PDF
Analysis of microcystins and nodularin in drinking water using an Agilent Ultivo triple quadrupole LC/MS
2018|Agilent Technologies|Aplikace
Application Note Analysis of microcystins and nodularin in drinking water using an Agilent Ultivo triple quadrupole LC/MS Figure 1. Agilent Ultivo Integrated into LC Stack. Authors Tarun Anumol1, Theresa Sosienski2, and Dan‑Hui Dorothy Yang2 1 Agilent Technologies, Inc. Wilmington, DE…
Klíčová slova
nodularin, nodularinmicrocystins, microcystinsultivo, ultivospike, spikedrinking, drinkingtriple, tripleadvisory, advisoryagilent, agilentwater, waterquadrupole, quadrupolehealth, healthpurchased, purchasedmicrocystin, microcystinexceptional, exceptionalmatrix
Sensitive Analysis of Nodularin and Microcystins of Concern in Drinking Water Using Simplified Sample Preparation
2018|Waters|Aplikace
[ TECHNOLOGY BRIEF ] Sensitive Analysis of Nodularin and Microcystins of Concern in Drinking Water Using Simplified Sample Preparation Stuart Oehrle, Douglas Stevens, Adam Ladak Waters Corporation, Milford, MA, USA Increased sensitivity with reduced run time, minimized sample preparation and…
Klíčová slova
microcystins, microcystinsnodularin, nodularindrinking, drinkingwater, waterbrief, briefconcern, concernchallenging, challengingspe, specurrent, currentwaters, watersincreased, increasedxevo, xevosimplified, simplifiednod, nodchallenge
Rapid and highly sensitive quantitation of Microcystins and Nodularin in water by modern LC-MS/MS
2024|Shimadzu|Postery
MP 163 Rapid and highly sensitive quantitation of Microcystins and Nodularin in water by modern LC-MS/MS Kate (Xiaomeng) Xia1, Evelyn Wang1, Ruth Marfil-Vega1, Yoshiyuki Okamura1, Tairo Ogura2 (1) Shimadzu Scientific Instruments, Columbia, MD 21046 U.S.A.; (2) Shimadzu Corporation, Analytical &…
Klíčová slova
nodularin, nodularinmicrocystins, microcystinsproliferating, proliferatingwater, waterwarmer, warmerepa, epaadvises, advisescyanotoxins, cyanotoxinsblooms, bloomsinterface, interfacealgae, algaetemperature, temperaturenutrient, nutrientmcs, mcssensitive
The Analysis of Cyanotoxins, Including Microcystins, in Drinking and Surface Waters by Liquid Chromatography-Tandem Quadrupole Mass Spectrometry
2017|Waters|Aplikace
[ APPLICATION NOTE ] The Analysis of Cyanotoxins, Including Microcystins, in Drinking and Surface Waters by Liquid Chromatography-Tandem Quadrupole Mass Spectrometry Julie Degryse,1 Marijn Van Hulle, 2 and Simon Hird3 Watergroep, Heverlee, Belgium; 2 Waters Corporation, Brussels, Belgium; 3 Waters…
Klíčová slova
conc, conccyl, cylnod, nodderr, derrxevo, xevoapplication, applicationresidual, residualnote, noteresponse, responseuplc, uplcwater, waterana, anamicrocystins, microcystinsorganisms, organismsbodies