Analysis of Camelid Single-Domain Antibodies Using Agilent AdvanceBio SEC 120 Å 1.9 μm and AdvanceBio HIC Columns
Aplikace | 2020 | Agilent TechnologiesInstrumentace
Spotřební materiál, LC kolony, GPC/SEC
ZaměřeníFarmaceutická analýza
VýrobceAgilent Technologies
Klíčová slovaabsorbance, mau, gln, min, vhh, advancebio, hic, sec, pyro, time, nanobodies, sdab, camelid, glutaminyl, nanobody, glu, proteins, mobile, phase, counts, igg, column, agilent, conversion, native, mab, hydrophobic, antibody, domain, motifs, fragments, heavy, hydrophobicity, terminal, attributes, lmw, here, hmw, characterize, protein, antigen, molecular, hydrodynamic, ptm, interaction, chain, size, separation, two, aggregates
Podobná PDF
Agilent Biocolumns - Aggregate/Fragment Analysis - Application Compendium
2021|Agilent Technologies|Příručky
Agilent Biocolumns Aggregate/Fragment Analysis Application Compendium Contents Background 2 Getting Started 3 How to Guide - Size Exclusion Chromatography for Biomolecule Analysis - 5991-3651EN 4 Featured Application Notes Elevate Your mAb Aggregate Analysis - 5994-2709EN 1 22 22 High-Resolution, High-Throughput…
Klíčová slova
return, returnsection, sectionmau, maucontents, contentssec, secinsulin, insulinmin, minprotein, proteinsize, sizemonomer, monomeradvancebio, advancebiotime, timeexclusion, exclusionaggregates, aggregatesaggregate
A Protein’s Journey
2020|Agilent Technologies|Prezentace
A Protein’s Journey Rita K. Steed LC Application Engineer June 11, 2020 1 July 2, 2020 A Protein’s Journey DE.5077777778 Outline LC techniques for biomolecule analysis Reversed phase • Commonly used, wide column choice denaturing conditions. Can be used for…
Klíčová slova
journey, journeyprotein, proteinadvancebio, advancebiointeraction, interactionpore, poremedia, mediaamino, aminomab, mabphase, phasesize, sizespent, spentbuffer, bufferhic, hicvolume, volumeinterstitial
Surmounting the Challenges of Bispecific Antibody Characterization
2021|Agilent Technologies|Aplikace
Application Note Biopharmaceuticals Surmounting the Challenges of Bispecific Antibody Characterization Using new optimized column chemistries to detect product impurities during manufacturing or storage Authors Andrea Angelo Tripodi, David L. Wong, JianQiu Mi, and Veronica Qin Agilent Tecnologies, Inc. Abstract Bispecific…
Klíčová slova
variants, variantsintact, intactamu, amunonidentical, nonidenticalemicizumab, emicizumabdeconvoluted, deconvolutedmain, mainchromatography, chromatographymab, mabmobile, mobilechains, chainsmau, maumass, massagilent, agilentcharacterization
Intact Analysis Using Hydrophobic Interaction - Agilent BioHPLC Columns Application Compendium
2020|Agilent Technologies|Příručky
Agilent-NISTmAb Intact Analysis Using Hydrophobic Interaction Agilent BioHPLC Columns Application Compendium Contents Agilent-NISTmAb Standard (P/N 5191-5744; 5191-5745) was aliquoted from NISTmAb RM 8671 batch. Quality control (QC) testing is performed using Agilent LC-MS system. QC batch release test includes aggregate…
Klíčová slova
hic, hicpage, pagehydrophobic, hydrophobicback, backcontents, contentsmab, maboxidized, oxidizedadvancebio, advancebiooxidation, oxidationinteraction, interactionprotein, proteinmonoclonal, monoclonalantibody, antibodymethionine, methioninechemistry